Questions and Answers

  • M
    Mr. Timothy JonesSep 1, 2025
    What does error 'E34: Insulation' mean on my Delta H2.5 Inverter?
    • L
      laurenjimenezSep 1, 2025
      The error 'E34: Insulation' on your Delta Inverter indicates an insulation issue. This could be due to a PV array insulation fault, so check the insulation of Solar inputs. It may also be caused by large PV array capacitance between Plus to Ground or Minus to Ground or both, so check the capacitance and dry PV panel if necessary. A final possibility is a detection circuit malfunction inside the inverter.
  • F
    fkirbyAug 31, 2025
    What does 'E26: OFR-Slow' mean on my Delta Inverter and how can I fix it?
    • T
      troy10Aug 31, 2025
      The 'E26: OFR-Slow' error on your Delta Inverter suggests that the actual utility frequency is over the OFR setting. To address this, check the utility frequency on the inverter terminal. Also, verify the country setting. If problems persist, the detection circuit inside the inverter may be malfunctioning.
  • M
    mary95Aug 30, 2025
    What does 'E28: UVR-Slow' mean on my Delta H2.5?
    • M
      mleeAug 30, 2025
      The 'E28: UVR-Slow' error on your Delta Inverter indicates a slow under-voltage condition. This can occur if the actual utility voltage is under the UVR setting, so check the utility voltage on the inverter terminal. Also, check the country or Grid setting. Another possible cause is a detection circuit malfunction inside the inverter.
  • K
    karen09Aug 29, 2025
    What does 'E13: OVR-Slow' mean on my Delta Inverter and how do I fix it?
    • C
      Christopher HansenAug 29, 2025
      The 'E13: OVR-Slow' error on your Delta Inverter indicates a slow over-voltage condition. This may be due to the actual utility voltage being over the OVR setting; check the utility voltage on the inverter terminal. Also, check the country and Grid settings. Another potential cause is a detection circuit malfunction inside the inverter.
  • D
    Daniel WallsAug 28, 2025
    Why does my Delta Inverter show 'E02: UFR' error?
    • J
      John GomezAug 28, 2025
      The 'E02: UFR' error on your Delta Inverter indicates that the actual utility frequency is lower than the UFR setting. To resolve this, check the utility frequency on the inverter terminal. Additionally, verify that the country and Grid settings are correct. If the issue persists, the detection circuit inside the inverter may be malfunctioning.
  • C
    Christina RyanAug 27, 2025
    Why does my Delta H2.5 Inverter show 'E01: OFR' error?
    • E
      Elizabeth JohnsonAug 27, 2025
      The 'E01: OFR' error on your Delta Inverter means that the actual utility frequency is higher than the OFR setting. Check the utility frequency on the inverter terminal. This error may also appear because of an incorrect country setting, so check it. Another reason could be detection circuit malfunction inside the inverter.
  • M
    Melissa GatesAug 26, 2025
    What does 'E10: UVR' mean on my Delta Inverter and how to fix it?
    • L
      lorimelendezAug 27, 2025
      The 'E10: UVR' error on your Delta Inverter indicates an under-voltage condition. This could be because the actual utility voltage is higher than the UVR setting, so measure the utility AC voltage to the inverter terminal. It might also be due to an incorrect country or Grid setting, which you should verify. Finally, a detection circuit malfunction inside the inverter could be the cause.
  • K
    Kiara BryantAug 25, 2025
    What does 'E11: OVR' mean on my Delta H2.5 and how can I fix it?
    • M
      michele64Aug 26, 2025
      The 'E11: OVR' error on your Delta Inverter indicates an over-voltage condition. This may be due to the actual utility voltage being higher than the OVR setting. You can measure the utility AC voltage at the inverter terminal to confirm this. It can also be caused by an incorrect country or Grid setting, which you should check, or a detection circuit malfunction inside the inverter.
  • E
    Emily WatkinsAug 25, 2025
    What should I do if my Delta H2.5 Inverter displays 'F35: HW Bus OVR'?
    • A
      Ashley ChandlerAug 25, 2025
      If your Delta Inverter shows a 'F35: HW Bus OVR' error, it could be due to several reasons. You should check the driver circuit for boost inside the inverter, or the Voc of PV array is over 510Vdc (H2.5) or 560Vdc (H3/ H3A/ H4A) - in this case, modify the solar array setting, and make the Voc less than 500Vdc (H2.5) or 550Vdc (H3/ H3A/ H4A). Another reason could be a defective detection circuit inside the inverter, or a surge during operation.