Chapter 13 Warning CodesMS300
542
ID No.
Display on LCD Keypad
Warning Name
Description
94
Copy PLC: size error
(CPLS)
Copy PLC capacity error
Action and Reset
Action Condition
Software detection
Action Time
Immediately act
Warning Setting Parameter
N/A
Reset Method
Manual reset
Reset Condition
Directly reset
Record
N/A
Cause
Corrective Actions
The PLC program copied to
MS300 exceeds the allowable
capacity
Check if the copied PLC program is for MS300
Use the correct capacity for the MS300 PLC program