Chapter 13 Warning CodesMS300
543
ID No.
Display on LCD Keypad
Warning Name
Description
95
Copy PLC: PLC
function (CPLF)
KPMS-LE01 Copy PLC function must be executed when
PLC is disabled.
Action and Reset
Action Condition
Software detection
Action Time
Immediately act
Warning Setting Parameter
N/A
Reset Method
Manual reset
Reset Condition
Directly reset
Record
N/A
Cause
Corrective Actions
PLC function is enabled when
KPMS-LE01 is running PLC copy
Disable the PLC function first, and then run the PLC copy function again.