EasyManua.ls Logo

Delta VFD007FP4EA-41 - Chapter 9 Specification; Specification

Delta VFD007FP4EA-41
404 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 9 Specifications |CFP2000 Series
9-1
Chapter 9 Specification
9-1 Specification
Frame Size
A B
Model VFD_ _ _ FP4EA- _ _ _ 007 015 022 037 040 055 075 110 150 185 220
Output Rating
Light duty
Rated output capacity (kVA) 2.4 3.3 4.4 6.8 8.4 10.4 14.3 19 25 30 36
Rated output current (A) 3 4.2 5.5 8.5 10.5 13 18 24 32 38 45
Applicable motor output (kW) 0.75 1.5 2.2 3.7 4 5.5 7.5 11 15 18.5 22
Applicable motor output (HP) 1 2 3 5 5 7.5 10 15 20 25 30
Overload tolerance
120% of rated current can endure for1 minute during every 5 minutes
Normal duty
Max. output frequency (Hz) 1.4 2.4 3.2 4.8 7.2 8.4 10 14 19 25 30
Carrier frequency (kHz) 2.8 3 4 6 9 10.5 12 18 24 32 38
Rated output capacity (kVA) 0.4 0.75 1.5 2.2 3.7 4 5.5 7.5 11 15 18.5
Rated output current (A) 0.5 1 2 3 5 5 7.5 10 15 20 25
Applicable motor output (kW)
120% of rated current can endure for1 minute during every 5 minutes
160% of rated current can endure for 3 seconds during every 30 seconds.
Input Rating
Max. output frequency (Hz) 599Hz
Carrier frequency (kHz) 2~15 (6kHz)
2~10
(6kHz)
Input current (A) Light duty 3.0 4.2 5.5 8.5 10.5 13 18 24 32 38 45
Input current (A) Normal duty 1.7 3 4 6 9.0 10.5 12 18 24 32 38
Rated voltage / Frequency
3-phase AC 380V~480V ( -15%~+10%), 50/60Hz
Operating voltage range 323~528Vac
Frequency tolerance 47~63Hz
Efficiency (%)
97 97 97 97 97 97 97 97 97 97 97
Power factor
>0.98 >0.98 >0.98 >0.98 >0.98 >0.98 >0.98 >0.98 >0.98 >0.98 >0.98
Weight
6.8kg 14.5kg
Cooling method
Natural cooling
Fan cooling
Braking chopper
Frame A to C (built-in)
DC choke
Built-in DC reactor EN6100-3-12
EMC Filter
Built-in EMC Filter EN61800-3 C1 & C2
Frame Size
C D0 D
Model VFD_ _ _ FP4EA- _ _ _ 300 370 450 550 750 900
Output Rating
Light duty
Rated output capacity (kVA) 48 58 73 88 120 143
Rated output current (A) 60 73 91 110 150 180
Applicable motor output (kW) 30 37 45 55 75 90
Applicable motor output (HP) 40 50 60 75 100 125
Overload tolerance
120% of rated current can endure for1 minute during
every 5 minutes
Normal duty
Max. output frequency (Hz) 36 48 58 73 88 120
Carrier frequency (kHz) 45 60 73 91 110 150
Rated output capacity (kVA) 22 30 37 45 55 75
Rated output current (A) 30 40 53 60 75 100
Applicable motor output (kW)
120% of rated current can endure for1 minute during
every 5 minutes
160% of rated current can endure for 3 seconds during
every 30 seconds.
Input Rating
Max. output frequency (Hz) 599Hz
Carrier frequency (kHz) 2~10kHz (6kHz)
2~9kHz
(4kHz)
Input current (A) Light duty 60 73 91 110 150 180
Input current (A) Normal duty 45 60 73 91 110 150
Rated voltage / Frequency
3 AC 380V~480V (-15% ~ +10%), 50/60Hz
Operating voltage range 323~528Vac
Frequency tolerance 47~63Hz
Efficiency (%)
97 97 97 97 97 97
Power factor
>0.98 >0.98 >0.98 >0.98 >0.98 >0.98
Weight
26.5kg 42kg 59.5kg
Cooling method
Fan cooling
Braking chopper
Frame A to C (built-in)
DC choke
Built-in DC reactor EN6100-3-12
EMC Filter
Built-in EMC Filter EN61800-3 C1 & C2
NOTE
The value of the carrier frequency is a factory setting. To increase the carrier frequency, the current needs to be decreased. See derating
curve diagram of Pr06-55 for more information.
When a load is a shock or impact load, use a higher level model.

Table of Contents

Related product manuals