4-16
Pr. Name of Parameter Setting
Factory
Setting
VF
FOCPG
FOCPM
malfunction
02-36
Input Terminals’ Status
at malfunction
0 ~ 65535 Read only
02-37
Output Terminals’ Status
at malfunction
0 ~ 65535 Read only
02-38
Hybrid servo drive’s
status at malfunction
0 ~ 65535 Read only
02-39
Detecting Braking
Resistor at startup
0: Disable, 1: Enable 1
02-40 Braking resistance 0.0 ~ 6553.5Ω 0.0
02-41
Limit of current 0 ~ 250% 200
02-42
Maintenance period of
the soft-start relay
0 ~ 65535 (X10)
0: Turn off the reminder of the remaining
lifespan of the soft-start relay.
0
02-43
Maintenance period of
the cooling fan.
0 ~ 65535 hour
0: Turn off the reminder of the remaining
maintenance hour of the cooling fan.
0