Chapter 4 Description of Parameters | VFD-VJ
4-18
Pr. Name of Parameter Setting
Factory
Setting
VF
FOCPG
FOCPM
03-15
Source of frequency
command
0: Digital keypad
1: RS485 Communication
2~5: Reserved
6: CANopen
0
03-16
Limit for the Slave
reverse
depressurization torque
0~500% 20
03-17 Slave’s activation level 0.0~100.0% 50.0
03-18
Reserved
03-19 Reserved
03-20
Start-up display
selection
0: F (frequency command)
1: H (actual frequency)
2: Multi-function display (user-defined
00-04)
3: A (Output current)
0
03-21
Slave reverse operation
for depressurization
0: Disabled
1: Enabled
2: Reserved
0
03-22 Slave closing level 0 ~400bar 400