Chapter 16 PLC Function ApplicationsMS300 (High Speed Model)
16-79
API
ASIN
Binary floating point number ASIN operation
133
D P
Bit device Word device
16-bit command
32-bit command (9 STEP)
DASIN Continuous
execution type
DASINP Pulse
execution type
Flag signal: none
X Y M K H KnX KnY KnM T C D
S
D
Notes on operand usage:
Please refer to the function specifications table for each device in
series for the scope of device usage
S: the designated source (binary floating point number). D: the ASIN value result.
ASIN value =sin
-1
The figure below shows the relationship between input data and result:
R
S
2
2
-
0 1,0-1,0
S: Input (SIN value)
R: Result (ASIN value)
When X0=On, the ASIN value obtained from the designated binary floating point
number (D1, D0) will be stored in (D11, D10), with the content consisting of a
binary floating point number.
X0
DASIN D0 D10
D 1 D 0
D 11 D 10
ASIN value
binary floating point
Binary floating point