EasyManua.ls Logo

DEMAG DC-Com 2 - Mains Connection Delay Fuse Links; Supply Lines 1

DEMAG DC-Com 2
124 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3.4.2 Mains connection delay fuse links
CAUTION
For safety reasons we recommend using 3-pole automatic circuit breakers / circuit breakers ( acc. to DIN EN
60898-1, tripping characteristics B or C) instead of individual fuses. Thus all poles are disconnected from the energy
source in the case of a short circuit.
Voltage 220-240 V 380-415 V 500-525 V 220-240 V 380-400 V 440-480 V 575 V
Frequency 50 Hz 60 Hz
Size
Motor size [A] [A] [A] [A] [A] [A] [A]
DC-Com 1
ZNK 71 A 8/2
6
6 6
6
6 6 6
ZNK 71 B 8/2
DC-Com 2 ZNK 71 B 8/2
DC-Com 5 ZNK 80 A 8/2
10 10
DC-Com 10
ZNK 100 A 8/2
ZNK 100 B 8/2 - 10 10 - 16 10 6
Tab. 11
Mains connection fuse link for hoist speeds until 09/2008 (no longer available)
Voltage 220-240 V 380-415 V 500-525 V 220-240 V 380-400 V 440-480 V 575 V
Frequency 50 Hz 60 Hz
Size
Motor size [A] [A] [A] [A] [A] [A] [A]
DC-Com 2 ZNK 71 B 8/4
6 6 6 6 6 6 6
DC-Com 5
ZNK 80 A 8/4
Tab. 12
3.4.3 Supply lines
Supply lines 1
15)
) for 5% voltage drop
Δ
U and start-up current I
A
Voltage 220-240 V 380-415 V 500-525 V 220-240 V 380-400 V 440-480 V 575 V
Frequency 50 Hz 60 Hz
Size
Motor size [mm
2
] [m] [mm
2
] [m] [mm
2
] [m] [mm
2
] [m] [mm
2
] [m] [mm
2
] [m] [mm
2
] [m]
DC-Com 1
ZNK 71 A 8/2
1,5
89
1,5
100
1,5
100
1,5
76
1,5
100
1,5
100
1,5
100
ZNK 71 B 8/2
DC-Com 2 ZNK 71 B 8/2
DC-Com 5 ZNK 80 A 8/2 67 56
DC-Com 10
ZNK 100 A 8/2
34 29 80
ZNK 100 B 8/2 - - 38 61 - - 26 43 59
Tab. 13
Supply lines for hoist speeds until 09/2008 (no longer available)
Voltage 220-240 V 380-415 V 500-525 V 220-240 V 380-400 V 440-480 V 575 V
Frequency 50 Hz 60 Hz
Size
Motor size [mm
2
] [m] [mm
2
] [m] [mm
2
] [m] [mm
2
] [m] [mm
2
] [m] [mm
2
] [m] [mm
2
] [m]
DC-Com 2 ZNK 71 B 8/4
1,5
100
1,5 100 1,5 100 1,5
100
1,5 100 1,5 100 1,5 100
DC-Com 5
ZNK 80 A 8/4 67 56
Tab. 14
15)
The lengths of the supply lines are calculated on the basis of an earth-loop impedance of 200 mΩ.
21480244/181209
23

Table of Contents