25
Error messages
NOTE
•An error message is displayed if Audyssey
®
Setup could not be completed due to speaker placement, the measurement environment, etc. If an error message is displayed, check the relevant items and perform the
necessary measures. Then perform Audyssey
®
Setup again.
•If the result still diers from the actual connection status after re-measurement or the error message still appears, it is possible that the speakers are not connected properly. Turn this unit o, check the speaker
connections and repeat the measurement process from the beginning.
•Be sure to turn o the power before checking speaker connections.
Examples Error details Measures
Audyssey Setup
Caution!
Microphone or Speaker is none
Please check the cable connection
and retry.
Retry
•The connected Setup and measurement microphone is broken, or a device
other than the supplied Setup and measurement microphone is connected.
•Not all speakers could be detected.
•Connect the included Setup and measurement microphone to the SETUP
MIC jack of this unit.
•Check the speaker connections.
Audyssey Setup
Caution!
Ambient noise is too high or level is
too low
Retry
•There is too much noise in the room for accurate measurements to be
made.
•Speaker or subwoofer sound is too low for accurate measurements to be
made.
•Either turn o any device generating noise or move it away.
•Perform again when the surroundings are quieter.
•Check the speaker installation and the direction in which the speakers are
facing.
•Adjust the subwoofer’s volume.
Audyssey Setup
Caution!:Please check the cable connection
and retry.
Front R None
Retry
•The displayed speaker could not be detected.
(The screen on the left indicates that the front right speaker cannot be
detected.)
•Check the connections of the displayed speaker.
Audyssey Setup
Caution!:Please check the cable connection
and retry.
Front R Phase
Retry Phase Info. Skip
•The displayed speaker is connected with the polarity reversed.
(The screen on the left indicates that the polarity phases of the front right
speakers are reversed.)
•Check the polarity of the displayed speaker.
•For some speakers, this error message may be
displayed even if the speaker is properly connected.
If you are sure the connection is correct, use p to
select “Skip”, then press ENTER.
Set up speakers (Audyssey® Setup)
Basic instructions
Advanced instructions
Information
Basic instructions
DVD

Table of Contents

Other manuals for Denon AVR-E300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Denon AVR-E300 and is the answer not in the manual?

Denon AVR-E300 Specifications

General IconGeneral
Channels5.1
HDMI Inputs4
HDMI Outputs1
3D Pass-throughYes
Audio Return Channel (ARC)Yes
Dolby TrueHDYes
DTS-HD Master AudioYes
NetworkingNo
AirPlayNo
Audyssey MultEQYes
HDMI Pass-ThroughYes
Receiver TypeAV Receiver
HDMI Ports Quantity5
Audio DAC192 kHz / 24-bit
Digital Sound Processor (DSP)Yes
Input Sensitivity200 mV
Response Bandwidth10 Hz - 100 kHz
Signal-To-Noise Ratio98 dB
Tuner BandsAM/FM
Amplifier TypeDiscrete
Frequency Response10 Hz - 100 kHz
BluetoothNo
Wi-FiNo
Output Power / Total375 W
Input Impedance47 kOhms
Video Inputs/OutputsComposite
Audio Inputs/OutputsDigital Optical
Power Output per Channel75 W (8 ohms, 20 Hz - 20 kHz, 0.08% THD)
Power Output75W (8 ohms, 20 Hz - 20 kHz, 0.08% THD, 2 channels driven)

Related product manuals