31
6. Test mode
6.1. Entering the test mode
The test mode is entered by pressing the
5
and
8
buttons simultaneously, plug the AC cord into a power outlet.
When the test mode is set, the "
1
" and "
3
" indicators light.
FL tube display when test mode entered
FL Display (The display part of 13 digits)
1 2 3 4 5 6 7 8 9 10 11 12 13
T E S T M O D E
When the test mode is set, the choice screen of the mode appears on the monitor.
6.2. Selecting the mode
The following modes are available.
(1) Laser on/off (CD/DVD/BD) mode : T2
(2) Error rate (skew) measurement mode : T7
(3) Accumulated laser on time display mode : TC
(4) Test mode cancel : TI
q
When the
9
button is pressed after entering the test mode, the display switches in the order: "T2, T7, TC, TI, T2
…"
FL Display (The display part of 13 digits)
1 2 3 4 5 6 7 8 9 10 11 12 13
T 2 L a s e r O n O f f
FL Display (The display part of 13 digits)
1 2 3 4 5 6 7 8 9 10 11 12 13
T 7 E r r o r R a t e
FL Display (The display part of 13 digits)
1 2 3 4 5 6 7 8 9 10 11 12 13
T C L a s e r O n T i m
FL Display (The display part of 13 digits)
1 2 3 4 5 6 7 8 9 10 11 12 13
T I T e s t E x i t
w
When the
8
button is pressed, the display switches in the opposite order from
q
above, starting from the current
position (for example, if currently at "TC", it switches as follows: "T7, T2 ").