Model | PowerScout HD Series |
---|---|
Frequency Range | 45-65 Hz |
Measurement Type | Power and Energy |
Voltage Range | 50 to 600V AC (depending on model) |
Current Input | Current Transformers (CTs) |
Communication Interface | RS-485, Ethernet |
Display | LCD |
Data Logging | Yes |
Storage Temperature | -20°C to 70°C |
Communication Protocol | Modbus |
Details the physical layout and user connections on the circuit board of the PowerScout HD meters.
Provides general safety information, compliance, and specifications for the PSHD family.
Outlines critical safety requirements for building service and meter installation.
Overview of the three methods for configuration and data viewing: ViewPoint HD, PSHD Web App, and LCD.
Details tasks to perform before installation to save time and reduce errors in the field.
Describes the typical work involved in physically installing the meter, performed by a licensed electrician.
Explains how to verify meter settings and communication after installation.
Step-by-step instructions for installing the ViewPoint HD software on a computer.
Details the four connectivity options available when launching the ViewPoint HD application.
Explains how to connect the meter to a computer via USB for power and communication.
Describes how to connect and configure the meter using Ethernet.
Guide on setting up electrical parameters like voltage input, service type, and CT types.
Details on setting up communication protocols like Modbus and BACnet.
Instructions for setting up conditional alarms for voltage and current.
Procedure for updating the meter's firmware using the ViewPoint HD software.
Illustrates different mounting options for PowerScout HD meters in various form factors.
Step-by-step guide for installing meters in wall mount enclosures.
Procedure for installing the PS3HD meter on a DIN rail.
Wiring diagram and instructions for a 3-wire, 1-phase service panel.
Wiring diagram and instructions for a 4-wire, 3-phase service panel.
Essential criteria and guidelines for selecting and installing current transformers (CTs).
Illustrates CT connection methods for multi-circuit PSHD meters.
Methods to confirm both physical interface and protocol settings are correct.
Details on configuring Modbus RTU and TCP settings for the meter.
Details on configuring BACnet MS/TP and BACnet IP settings for the meter.
Explains the two levels of PIN protection for restricting meter access.
Simple checks to ensure correct CT phasing and direction after installation.
Guidance on checking and correcting CT orientation for accurate power reporting.
Explanation of THD measurement and its interpretation for power and current.
Describes how registers are organized into functional groups based on the SunSpec model.
Tables detailing how to configure element and channel registers for various service types.
Lists and describes the Modbus RTU commands supported by the meter.
Explains how to handle 32-bit IEEE 754 formatted floating point numbers for registers.
Details the Building Automation and Control Network (BACnet) protocol.
Step-by-step instructions for installing ViewPoint HD for the first time.
Procedure for updating ViewPoint HD software when a previous version is installed.
Guidance on resolving common issues encountered during software installation.
Details on hardware, protocols, baud rates, and data formats for communication.
Information on wire connections, mounting, enclosure, and operating temperature.
Lists FCC compliance, UL recognition, UL listing, and other safety certifications.