EasyManua.ls Logo

Dickert Electronic DCM31 - Page 19

Dickert Electronic DCM31
35 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Motor control unit DCM31
19 / 35
Basic values
Menu
Value
range
Function / values
[M
.
A0]
=
00
2-leaf.-Hinged
gate
[M
.
A0]
=
01
1-leaf.-Hinged
gate
[M.A0] = 02
Sliding gate
[M.A0] = 03
Folding gate
[M
.
A0]
=
04
Roller
shutter gate
[M.A0] = 05
Type 5
[M.A0] = 06
Type 6
[M.A0] = 07
Type 7
Setting
C1
00
01
1- / 2- LEAF MODE
2- leaf mode
1- leaf mode
00
01
01
00
01
00
00
00
C2
00
01..19
20
Closing delay in 2-leaf mode
No closing delay
Closing delay in 0.5sec steps
Closing delay is automatically learnt
20
00
00
03
00
20
20
20
C3
00
01..19
Open delay in 2-leaf mode
No opening delay
Opening delay in 0.5sec steps
04
00
00
03
00
04
04
04
C4
00
01
02
03
04
05
Relay output OUT function
Electric lock (during startup time, see menu A6)
Photoelectric barrier test
Status display: gate in OPEN end position
Status display: gate in CLOSE end position
Radio module function 8 and 9 (if current surge drop after 10min)
Forward Open command
00
00
02
03
00
00
00
00
C5
00..99
Running time limit
in 1 sec steps, 1 sec..100sec
99
99
99
15
99
99
99
99
C6
00
01
02
Type of LIMIT SWITCH
Internal limit switch (in the motor cable)
External limit switch (connected to terminals 16-21)
No limit switch (electricity stop only) only permissible with safety strips!
01
01
01
02
01
01
01
01
C7 00 -
C8 00 -
C9 00 -
d0 00 -
d1 00 -
d2 00 -
d3 00 -
d4 00 -
d5 00 -
d6 00 -
d7 00 -
d8
00
01
Service mode
control panel free, menu items adjustable
control panel blocked, menu items not adjustable
Switchover: emergency stop, Simultaneously press + key
and – key ,
Switchover with menu key
00
00
00
00
00
00
00
00
d9
00
01
02
03
04
05
Trip counter (read only, cannot be changed)
100,000 digit
10,000 digit
1,000 digit
100 digit
10 digit
1 digit

Table of Contents