Motor control unit DCM31
18 / 35
Basic values
Menu
Value
range
Function / values
.
=
2-leaf.-Hinged
.
=
1-leaf.-Hinged
[M.A0] = 02
Sliding gate
[M.A0] = 03
Folding gate
.
Roller
[M.A0] = 05
Type 5
[M.A0] = 06
Type 6
[M.A0] = 07
Type 7
Setting
b6
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
CLOSING EDGE SAFETY DEVICE function
8k2 opening: no effect closing: no effect
8k2 opening: no effect closing: stop
8k2 opening: no effect closing: release
8k2 opening: no effect closing: reversing
8k2 opening: stop closing: no effect
8k2 opening: stop closing: stop
8k2 opening: stop closing: release
8k2 opening: stop closing: reversing
8k2 opening: release closing: no effect
8k2 opening: release closing: stop
8k2 opening: release closing: release
8k2 opening: release closing: reversing
8k2 opening: reversing closing: no effect
8k2 opening: reversing closing: stop
8k2 opening: reversing closing: release
8k2 opening: reversing closing: reversing
OSE opening: no effect closing: no effect
OSE opening: no effect closing: stop
OSE opening: no effect closing: release
OSE opening: no effect closing: reversing
OSE opening: stop closing: no effect
OSE opening: stop closing: stop
OSE opening: stop closing: release
OSE opening: stop closing: reversing
OSE opening: release closing: no effect
OSE opening: release closing: stop
OSE opening: release closing: release
OSE opening: release closing: reversing
OSE opening: reversing closing: no effect
OSE opening: reversing closing: stop
OSE opening: reversing closing: release
OSE opening: reversing closing: reversing
10
10
10
02
02
02
02
02
b7
00..15
Release time
Release time in 0.25 sec steps, 0.25..4.00 sec
07
07
01
07
07
07
07
07
b8
00
01
02
EMERGENCY STOP input function
Automatic closing blocked after emergency stop
Closing time runs again after emergency stop release
After emergency stop next run in start travel, automatic closing blocked
00
00
00
00
00
00
00
00
b9
00
01
02
03
04
05
06
07
08
09
Function of inputs A/B and radio receiver
A: Open pulse + panic B: Close pulse + panic
A: Open pulse + panic B: Close pulse
A: Open pulse + panic B: Close dead man
A: Open pulse B: Close pulse + panic
A: Open pulse B: Close pulse
A: Open pulse B: Close dead man
A: Open dead man B: Close pulse + panic
A: Open dead man B: Close pulse
A: Open dead man B: Close dead man
A: Pulse (open-stop-close-...) B: Active leaf / partial opening
00
00
00
00
00
00
00
00
C0
00
01..99
Duration of the PARTIAL OPENING
Active leaf mode (only in 2-leaf mode)
Running time until partial opening/ventilation position in 0.5 sec steps
00
10
10
00
02
00
00
00