3.18
Description
S1 RING count
Number of ring in a period of 8 seconds.
Value Unit Function
0 RING No ring in a period of 8 seconds
1-5 RING RING count
Default=0 Type:Non Storable
S2 ESCAPE sequence character
Value Unit Function
0-127 ASCII Contain the ESCAPE sequence character. If the value is greater then 127, escape sequence
is disabled.
Default=43 Type:Storable
S3 CARRIAGE RETURN character
Value Unit Function
0-127 ASCII Contain the CARRIAGE RETURN character
Default=13 Type:Non-storable
S4 LINE FEED character
Value Unit Function
127 ASCII Contain the LINE FEED character
Default=10 Type:Non-storable
S5 BACKSPACE character
Value Unit Function
0-127 ASCII Contain the BACK SPACE character
Default=8 Type:Non-storable
S7 Wait time for connection
Value Unit Function
0-255 sec. In originate maximum amount of time to wait between end of dialing and the connection.
Default=25 Typr:Storable
S12 Escape prompt delay
Value Unit Function
0 ms No escape prompt delay
0-255 20ms Define escape prompt delay before, during, and after the ESCAPE sequence, so that the
escape sequence can be valid.