Description
3.19
S13 Call Waiting time
Value Unit Function
0 sec. Call Waiting time disable
0-255 1 sec. Defines the duration of buzzer/TEST led flash when arrives a new call.
Default=30 Type:Storable
S25 DTR control
Value Unit Function
0-255 sec/100 Sets the length of time that the modem will ignore DTR for before hanging up.
Default =5 Type:Storable
S26 RTS/CTS (C105/C106) delay
Value Unit Function
0-255 10 msec. In syncronous mode, defines the RTS/CTS delay (refer also &R command).
Default =1 Type:Storable
S31 V25bis command mode selector
Bit-mapped register.
Select either the AT command mode or of the supported V25bis command modes.
All bits = 0 AT command mode
Bit 1-0 = 00 V25bis Async
= 01 Non available
= 10 Non available
= 11 Non available
Bit 7 = 0 V25bis disabled
= 1 V25bis enabled
Default=0 Type: Non-storable
S34 Pointer for Autologon and Call-Back services
Establishes selection of the memory location the modem uses to initiate Autologon or Call-
Back procedure.
0 - 19 phonebook location for Autologon or Call-Back procedure.
20 phonebook scroll
255 function disable
Default =255 Type: Storable
S37 DCE speed
Select the speed connection thruogh the selected V.110 rate adaption protocol (see ATN
command).
0, 255 Last AT command speed
4 = 600 bps
5 = 1200 bps