7 Configuration
SAFEONE DN3PD2 Manual 26
7.6 Machine data
The "Machine data" calculation tool can be used to determine fmin and fmax.
Enter the machine-specific data and the tool calculates the associated frequencies. The ma-
chine data can be saved in the device. Check the checkbox "Take over machine data". Then it
is no longer possible to enter the frequencies directly in the "Parameterization" menu.
7.7 Read out the project
You can read out the parameterization saved on the safety relay.
No password is required for reading out.
► Start the configuration software
► Open the "Interface" menu item and select the COM port.
► Open the "Parameterization" menu item.
► Click the "Read out device" button.
7.8 Create a project
► Start the configuration software.
► Open the "Interface" menu item and select the COM port.
► Open the "Parameterization" menu item.
► Edit the parameter.
► Transmit the project to the device with the button „save on device“.
► There is always a password prompt. If no password is saved, confirm the query with
"ok".
► Confirm the settings
► Save the project
7.9 Edit and Change password
Protect your safety relay against unauthorized access with a device password.
► Open the menu item "Parameterization password"
► Enter the current password. If no password is assigned, the field can remain empty.
► Edit a new password and confirm it.
► Click the button “Write to device”.
The password is now stored in the device and must be specified when transferring a new pro-
ject or when validation.