Controls on the ground
Select a stable, level work area free of
obstacles.
Position the key-operated switch of the
truck panel on the controls on the ground;
the LCD must light up without showing
any error message.
Note: in cold climates, the LCD display
requires a short warm up time before
lighting up.
Turn the ignition key on the symbol
representing the truck.
Emergency stop test
Press the red emergency stop button by
turning it to the OFF position: the system
must switch off and no function can be
operative.
Turn the red stop emergency button to the
ON position.
Testing the machine functions
Do not activate the movement enable key.
Activate each of the platform and boom
functions buttons: the boom and platform
functions must not be operative.
Activate the movement enable key and
activate each of the boom and platform
functions buttons: all the platform and
boom functions must be operative for a
complete cycle.
Auxiliary pump test
Press the red emergency stop button:
reset it.
Activate the auxiliary pump and test the
movements of the booms and platform.
NOTE: to avoid consuming the batteries,
limit the test duration time.
After confirming the correct working,
deactivate the auxiliary pump.
Testing the warning sound
Press the yellow button of the warning
sound and check its working.
Checking the errors
Select from the control panel the alarm
pages and check for the absence of
alarms.
If this is not the case, immediately
proceed with solving the problem.
Controls on the platform
Position the key-operated switch of the
trucks control panel on the controls in the
platform.
Emergency stop test
Press the red emergency stop button on
the platform by turning it to the OFF
position: the system must switch off and
no function can be operative.
Turn the red stop emergency button to the
ON position.
Testing the pedal switch
Press the red emergency stop button on
the controls in the platform, bringing it to
the OFF position.
Turn the red emergency button to the ON
position.
Do not press the pedal switch down and
test each function of the machine: none of
the functions must be operative.
Press the pedal switch and try to make an
operation of any functional motion: any
motion should be ok.
Testing the machine functions
Do not press the movement enable pedal.
Activate the functions of the joysticks for
movement and telescopic booms: the
functions must not be operative.