A-3 Auxiliary pump test
Press the red emergency button and reset it.
Activate the emergency pump and test the
movements of the booms and platform.
NOTE: to avoid consuming the batteries, limit
the test duration time.
To confirm the correct working, deactivate the
emergency electric pump and restart the
system.
A-4 Overload Sensor - checking
How much the load weighted by the overload
sensor is in the platform will be indicated on
the panel on the ground control console. If the
load in the platform does not exceed rated
load, the vehicle is safe during work.
Otherwise, it is dangerous and the alarm will
be activated. So, it is important to make sure
the sensor is in good condition before starting
work every day.
Bolt -checking
Check if there is some bolts is slacken or
missing and the sensor undamaged. If there is
abnormal condition, ask for help from DingLi or
your agency.
Overload Sensor - checking
It is critically important for safety of life and
property of operators to make sure the sensor
works well. Checking and Making sure the
sensor is in good condition before starting
work every day could protect operators from
danger. When there is some collision on
platform, stop working and to check if the
sensor is well. The procedures as follows:
1 Vehicle Condition Interface indicating
data on vehicle condition can be entered
by depressing down the Data button on
the ground control contation.