© 2003 Directed Electronics, Inc. Vista, CA 27
features menu
The factory default settings are indicated in bold text in the table below.
FEATURE DEFAULT - LED ON SETTING LED OFF SETTING
NUMBER (PRESS CHANNEL 1) (PRESS CHANNEL 2)
1 Engine checking on Engine checking off
2 Tachometer checking type Voltage checking type
3 12 minutes run time (1)* 24 minutes (2)*, 60 minutes (3) run time
4 Flashing parking light output Constant parking light output
5 Cranking time 0.6 sec. (1) Cranking time 0.8 (2), 1.0 (3), 1.2 (4), 1.4 (5),
1.6 (6), 1.8 (7), 2.0 (8), 4.0 (9) sec.
6 Voltage check high level Voltage check low level
7 No function
8 Activation pulse: 1 (1) Activation pulses: 2 (2), 3 (3)
9 Ignition/accessory output: Ignition Ignition/accessory output: Accessory
10 Accessory state during wait to start: OFF Accessory state during wait to start: ON
11 2
nd
status output: Normal Rear defogger latched/pulsed
12 No function
13 No function
14 No function
*NOTE: The number in parentheses indicate the number of times the LED will flash