21
TOTAL SALES - Press key “6”
Shows total sales since machine manufacture or last
MAS-TER RESET. This total is not cleared by
CLEAR TOTALS. Press the number “6” on the
keypad, the display will scroll “TOTAL SALES” then
change to $#.##. Press the “CLR” key to return to
“SETUP MODE”.
ENABLE HEALTH CONTROL - Press key “7”
Allows the service technician to select items to
ENABLE HEALTH CONTROL. When enabled, if the
temperature in the vender does not reach 45
degrees F within 30 minutes after the service door is
closed, a “HEALTH TIME” error will occur and
lockout the enabled selection(s) from vending until
after the error is cleared. Also, if the temperature in
the vender goes above 41 degrees F for more than
15 minutes after the initial cool down period, a
“HEALTH CONTROL” error will occur and lockout
the enabled selection(s) from vending until the error
is cleared. Press the number “7” on the keypad and
the display will scroll “ENABLE HEALTH
CONTROL”. Press the “*” key and the display will
show ‘ITEM”. There are now three choices:
1. All selections. Press the * key and all
selections in the vender will now be set for
health control. The display will change to
“ENABLED” then back to “ITEM”.
2. One tray. Pressing the letter of the shelf
followed by the * key will set control for all
selections on that shelf. For example, to
control the A shelf push key “A” followed by
“*” key. The display will change to
“ENABLED” then back to “ITEM”.
3. Single selection. Press the desired
selection number or numbers corresponding
to the selections that require the health
control function. After each selection is
made the display will change to “ENABLED”
then back to “ITEM”.
Press the keypad buttons again and the display will
flash “DISABLED” and return to “ITEM”. Priority will
be given to the higher ranked method If one
selection on the A tray was set to ENABLE using
option 3 above and you wish to change the
remaining selections on that tray using option 2, the
Setting for the entire tray would take precedence.
Conversely, if the tray was set using option 2 first
followed by the single selection using option 3, the
setting for the remainder of the shelf would remain
and the new price for the single selection would
change to the new value. Press “CLR” to return to
“SETUP MODE
DROP SENSOR ENABLED/DISABLED - Press key
“8”
(PASSWORD REQUIRED)
Allows Enabling or Disabling of drop sensor Credit
Guard function. When enabled, the customer will
retain credit for the amount deposited if a product
does not pass through the sensor beam in the
recovery unit. This state will allow three attempts to
vend a product before credit is lost. Both states will
prevent a vend if a product is in the recovery unit.
Press the number “8” on the keypad and “ENABLE
DROP SENSOR” or “DISABLE DROP SENSOR” will
scroll across the display. Pressing the “*” key will
switch the state. Press the “CLR” key to return to
“SETUP MODE”.
SET COOL TIME - Press key “9”
Allows the service technician to vary the time
duration of the cool down period from 0 to 255
minutes. If no time is entered here, and the SET
COOL DOWN feature is started, the time duration of
the cool down period will be 240 minutes (4 hours).
To set the cool down time press the letter “D” on the
keypad and the display will scroll “SET COOL
TIME”, and then change to “COOL 240”. Use the
keypad to enter the duration of the cool down period
that you wish to use. Press the “*” key to enter your
preferred time into memory. The display will read
“OK” momentarily and return to “SETUP MODE”.
ENTER NEW PASSWORD - Press key “0”
(PASSWORD REQUIRED)
Allows the service technician to enter a personalized
password. IF YOU DECIDE TO CHANGE FROM
THE DEFAULT PASSWORD, PLEASE ENTER THE
NEW PASSWORD SLOWLY AND CAREFULLY!!!
Press the number “0” on the keypad and “ENTER
PASSWORD” will scroll across the display. Press
the “*” key and the display will read “PW”. Enter the
password, the display will read “OK” momentarily
then “NEW PW” will be displayed. Enter the new
password. After the fourth character of the new
Password is entered the display will read “OK”
momentarily and return to “SETUP MODE”.