7000 Series Installation and Programming Guide | Digital Monitoring Products 9
PROGRAM THE PANEL
Before continuing with programming and setup, you’ll program the keypad in the panel as a device.
To access the Programmer menu, reset the panel, enter 6653 (PROG), then press CMD.
After completing each of the following steps, press CMD to advance to the next option. Refer to the panel
programming guide as needed.
Device Setup
Advance to Device Setup, then press a select key to enter the setup menu.
Device Number
Set the keypad address from 1-8 for XT30, XT50, and XR150 Series panels, or 1-16 for
XR550 Series panels.
Device Name
Enter the name for the device.
Device Type
For use as a standard keypad, select KPD. For use as an access control keypad, press
any select key, then select DOOR.
Communication Type
Ensure the COMM TYPE is set to KPD (Keypad Bus).
Configure additional options as needed. To configure the custom card options for the keypad, do not program CARD
OPTIONS in Device Setup.
DEVICE SETUP
DEVICE SETUP
DEVICE NO: -
DEVICE SETUP
*UNUSED*
DEVICE SETUP
TYPE: KEYPAD
DEVICE SETUP
COMM TYPE: KPD

Other manuals for DMP Electronics Thinline Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DMP Electronics Thinline Series and is the answer not in the manual?

DMP Electronics Thinline Series Specifications

General IconGeneral
BrandDMP Electronics
ModelThinline Series
CategoryKeypad
LanguageEnglish

Related product manuals