EasyManuals Logo

DMP Electronics Thinline Series Installation Guide

DMP Electronics Thinline Series
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #22 background imageLoading...
Page #22 background image
20
Zone 3 Exit (7073/A, 7173)
Select YES to enable the Request to Exit feature on Zone
3. When Zone 3 shorts, the keypad relay activates. During
this time, the user can open the protected door to start
the programmed bypass entry/exit timer. If the door is not
opened within the time programmed in the Zone 3 REX
Strike Time, the relay restores the door to its locked state.
No panel programming is required.
Zone 3 REX Strike Time (7073/A, 7173)
Enter the number of REX seconds to elapse. Range is from 5
to 250 seconds. Press any select key to enter the number. The
default is 5 seconds.
Arming/Disarming Wait Time (7063/A, 7073/A, 7163, 7173)
Select the number of seconds (1-9) the keypad should wait
when an area system displays ALL? NO YES during arming/
disarming or a HOME/SLEEP/AWAY system waits during arming
only. If NO or YES, or HOME, SLEEP, or AWAY is not manually
selected before the delay expires, the keypad automatically
selects the YES or the AWAY key. Select zero (0) to disable this
feature. The delay also occurs when any credential is presented
for arming the Home/Sleep/Away system.
ACTIVATE ZONE 3
EXIT: NO YES
ZN 3 REX STRIKE
TIME: 5
ALL?: NO YES
DELAY: 2
Installer Options

Other manuals for DMP Electronics Thinline Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DMP Electronics Thinline Series and is the answer not in the manual?

DMP Electronics Thinline Series Specifications

General IconGeneral
BrandDMP Electronics
ModelThinline Series
CategoryKeypad
LanguageEnglish

Related product manuals