XR500 Series Installation Guide Digital Monitoring Products
25
COMPLIANCE
Central-Station and Proprietary Burglar-Alarm Units
ANSI/UL 1610 AND ANSI/UL 1076
24.1 Opening/Closing Reports
The Opening/Closing Reports option must be programmed as YES.
24.2 Closing Wait
The Closing Wait option must be programmed YES.
24.3 Entry Delay
The maximum entry delay used must not be more than 60 seconds when using Model 350A or 350H Attack Resistant
Housing.
24.4 Exit Delay
The maximum exit delay used must not be more than 60 seconds.
24.5 Proprietary Dialer
The Model XR500 Series provides proprietary service when congured as a digital dialer.
24.6 DACT Central Station
DACT Central Station service can be provided under by adding an Ademco AB12M bell and bell housing and placing
the Model XR500 Series panel into Model 350A or 350H Attack Resistant Housing.
24.7 Bell Cuto
The Bell Cuto time cannot be less than 15 minutes.
24.8 Standard or Encrypted Line Security
Standard Line Security is provided when congured as a Path 1 NET system using an XR500N panel. The NET Check-in
time must be set to 03 minutes or RND. When programmed for Standard Line Security, Exit Time Restart is disabled.
When a dialer is required for 06 minute check-in time, an attack resistant enclosure (DMP Model 350A or 350H) is
required. When the check-in time is set to a number less than 200 seconds, an attack resistant enclosure is not
required.
To provide Encrypted Line security, install an XR500E panel.
For Encrypted Line security operation, communication between the Premise and Supervising Station provides 128 bit
encryption when using an XR500E panel.
The XR500 Series Protected Premises Control Unit is suitable for Standard Line Security service when congured for
NET communication with SCS-1R receiving system. This conguration is approved for the following:
AMCX - Central Station Alarm Units
APOU - Proprietary Alarm Units
24.9 Wireless Audible Annunciation Option
The Wireless Audible option must be selected as ANY for commercial applications.
24.10 CELL Only, Standard or Encrypted Line Security
Standard or Encrypted Line Security is provided when programmed using Model 463C, 464-263C or 464-263H for CELL
with no backup. XR500 cellular communication is used as primary with a 3 minute check-in when armed or disarmed.
Path 1 programming
Comm Type: = CELL Checkin: = 3 minute
Path Type: = Primary Fail Time: = 3 minute
Encrypt: = NO or YES* Test Rpt: = NO
Sub Code: = NO or YES
*For Encrypted Line Security, program a Passphrase in Network Options.