16 XTLtouch System User Guide | Digital Monitoring Products, Inc.
ACCESSING THE USER MENU
To access your user menu follow these steps:
1. Select Keypad from the carousel
menu and press CMD until MENU?
NO YES displays.
2. Select YES and enter your user
code. Then press CMD.
SENSOR RESET
Use the sensor reset function to reset smoke
detectors, flood detectors, and temperature
sensors after an alarm.
FAVORITES
You can create groups of up to 25 Z-Wave
devices per favorite. The 20 available
favorites can only be activated, not turned
on and o.
For example, turning the lights on and
unlocking the front door would be one
favorite. Turning the lights o and locking
the front door would be a separate favorite.
Z-WAVE SETUP
Allows you to program Z-Wave devices into
your system.
ADD: Add up to 140 Z-Wave
devices to your system.
LIST: Displays a list of Z-Wave
devices already added to your
system.
REMOVE: Remove a Z-Wave device
from your system.
FAV: Add, edit, or remove a favorite.
XFER: Transfer Z-Wave device
information into your system
from a separate system.
OPT: Optimize the communication
path Z-Wave devices use to interact
with your system.

Other manuals for DMP Electronics XTLtouch

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DMP Electronics XTLtouch and is the answer not in the manual?

DMP Electronics XTLtouch Specifications

General IconGeneral
BrandDMP Electronics
ModelXTLtouch
CategorySecurity System
LanguageEnglish

Related product manuals