MODES OF OPERATION Smart Touch Cabin Control Installation & Operations Manual
22 L-3380 ENGLISH
Figure 38: Smart Touch
High Pressure Fault Help
a. Fault Help Lookup
i. Air Sensor Fault Help
ii. High Pressure Fault Help
iii. Low Pressure Fault Help
iv. Low AC Fault Help
v. Pump Sentry Fault Help
vi. Lost AC Fault Help
vii. Seawater Low Temperature Limit Fault Help
Figure 39: Smart Touch
QR Code Link for More Help
b. Link to Get More Help Lets you scan a QR code to access the Smart
Touch website to obtain more Smart Touch help.
Figure 40: Smart Touch
Troubleshooting and Commissioning
3. Commission Procedure Provides instructions on how to commission a unit.
It lets you have the main inputs and outputs of the unit tested, step by step.
Steps vary depending on DX or CW. Successful completion will add an entry
into the Fault History screen.
FAULT HANDLING, HISTORY & RUN HOURS
To protect the equipment, certain fault conditions trigger a lockout: The control shuts
down and will not restart until the fault is repaired. The lockout condition depends on a
combination of the failsafe level programmed, as well as the type of fault detected. All
of these options have a CLEAR icon. Pressing this icon clears the visible fault history,
compressor run hours, and fan run hours. Pressing and holding the CLEAR icon for
10 seconds will bring back the lifetime fault history and run hours.
Figure 41: Smart Touch
Fault & Hours Settings
One of the following fault codes displays when a fault is detected:
Air Sensor Failure - Indicates air sensor failure.
Filter needs to be Cleaned or Replaced - Indicates filter needs to be
cleaned or replaced.
High Pressure Fault - Indicates high refrigerant pressure. When in Heat
Mode, it does not display and does not cause lockout.
Low AC Voltage - Indicates low AC voltage.
Low Pressure Fault - Indicates low refrigerant pressure. It has a 10-minute
shutdown delay.
Pump Sentry Fault - Indicates high water temperature in condensing coil.
Lost AC Fault - Indicates loss of power.
Seawater Low Temperature Limit Fault - Indicates the seawater temperature is below 40°F (4.4°C).