MODES OF OPERATION Smart Touch Cabin Control Installation & Operations Manual
28 L-3380 ENGLISH
HVAC Control
Settings
(continued)
DX Operational
Settings
Page 1
Compressor Start Delay 5 sec 135 sec 15 sec
Failsafe Level Faults Not Detected / Faults Detected But
Not Displayed / Faults Detected and
Displayed / Faults Detected and
Displayed with Lockout
Faults Detected and
Displayed with Lockout
Low-Voltage Monitor Off/75-120V AC or Off/175-240V AC Off
Page 2
De-Ice Cycle Disabled / Enabled with 5°F/3°C Sensor
Differential / Enabled with 7°F/4°C
Sensor Differential
Enabled with 5°F/3°C
Sensor Differential
Pump Sentry Off/100-150°F or Off/40-65°C Off
Pump Operational Mode Continuous or Cycled Continuous
Page 3
Low Pressure Detection Set by Jumper / Disabled Set by Jumper
Seawater Low Limit
Adjustment
[35-50°]F 40°F
CW Operational
Settings
Page 1
Water Valve Force Open Off/On Off
Water Temp Differential 5°F/3°C 25°F/14°C 15°F/8°C
Page 2
Memorize
Settings
Recall Memorized
Settings
Recall Factory
Default Settings
Table 1: Main Menu – Programmable Parameters (continued)
Main
Category
Item Sub Item 1 Sub Item 2 Sub Item 3
Range
(min/max) or
Choices Factory Default