PSS5000/INGU/805799/09 23 of 27
PSS 5000 – Installation Guide
4 Technical Data
4 Technical Data
General information
Only equipment approved by Doms ApS is permitted to be installed in the
PSS 5000 Forecourt Controller.
The cables connecting the Hardware Interface Modules (HIMs) to the fore-
court devices should be twisted pair with a braided shield and with a mini-
mum 80% cover.
It is important that both ends of the cable shield are connected correctly.
Physical data
The physical parameters of the PSS 5000 have the following values:
Environmental data
The environmental parameters of the PSS 5000 have the following values:
Physical Parameter Standard Compact
Dimensions (H x W x D) 600 x 200 x 124 mm
(23.5 x 7.9 x 4.9 inches)
363 x 200 x 100 mm
(13.3 x 7.9 x 3.9 inches)
Weight (approx. incl. HIMs) 8 kg (17.6 lbs) 5kg (11 lbs)
Ingress protection IP30 IP30
Environmental
Operating temperature range -30°C to +55°C
Storage temperature range -30°C to +55°C
Ambient humidity Max. 90% RH, non-condensing
Electromagnetic Environment Class (E1)
(OIML D11 2004: residential, commercial and light industrial building)
Mechanical Environment Class (M1)
(MID, 2004/22/EC D11 2004), (locations with vibration and shocks of low signifi-
cance)