Cabinet Collector, Models 54-90
32
Problem Probable Cause Remedy
Insufficient airflow Collapsed or plugged duct Clean duct of all debris. Replace collapsed duct.
Improper duct sizing Contact installer of dust collection equipment.
EZ Filter Pack plugged Shake filter packs a minimum of once a day. Brush
or manually clean filter packs plugged with sticky or
fibrous material. Replace filter packs that do not clean
properly by shaking. See EZ Filter Pack Installation.
Manual shaker mechanism
malfunctioning
Check that the roll pin is in place. Replace if necessary.