A Series Diesel Engine Engine Replacement and Testing 227
Operate the engine at idle for 5 to 10 minutes and
check for leaks and loose parts.
Engine Testing
Verify engine performance by performing an in-chassis check.
Operating Conditions for Run-In and Test
Measurement Limit (s)
Coolant Temperature ּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּ 100 [212] Maximum
Lubricating Oil Temperature ּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּ 120 [248] Maximum
Lubricating Oil Pressure ּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּ 294 kPa [42.6 PSI] Minimum
Air Inlet Temperature ּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּ 25 [77] Maximum
Air Inlet Restriction ּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּ 250 mmHg Maximum
Boost Pressure ּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּ 66cm [26 in.] Hg Minimum
Exhaust Temperature ּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּ 630 [1166] Maximum
Smoke
Bosch Smoke Meter ּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּ 2.5 Units Maximum
Celsco Smoke Meter ּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּּ 4% Opacity Maximum