Operating & Maintenance Manual Operating Instructions
42
Operating Instructions
Prior to Starting
1. Place the unit in a position that is as level as possible. The design of the unit
permits a 15 degree lengthways and sideways limit on out of level operation. It
is the engine, not the compressor, that is the limiting factor.
When the unit has to be operated out of level, it is important to keep the engine
oil level near the high level mark (with the unit level).
CAUTION
!
Do not overfill either the engine or the compressor with oil.
2. Check the engine lubrication oil in accordance with the operating instructions
in the Engine Operator's Manual.
3. Check the compressor oil level in the sight glass located on the separator tank.
4. Check the diesel fuel level. A good rule is to top up at the end of each working
day. This prevents condensation from occurring in the tank.