Operating & Maintenance Manual Operating Instructions
50
Starting the Machine
Under no circumstances should volatile liquids such as Ether be used for
starting this machine.
All normal starting functions are incorporated in the key operated switch.
• Turn the key switch to position 1. The engine fault and compressor fault lamps will
flash.
Wait to Start Lamp.
• Turn the key switch to position 1 until the Wait To Start Lamp. (14) extinguishes.
• Turn the key switch to crank position (3) (engine start position)
NOTE: Position (2) not used on AWJD models.
• Release to position (1) when engine starts. The engine will now be running at a
reduced speed.
At temperatures below 0°C or if there is difficulty starting first time:
• Open the service valve fully, with no hose connected.
• Complete starting sequence above.
• Close service valve as soon as engine runs freely.
• Do not allow machine to run for long periods with service valve open.
• Allow the engine to reach operating temperature.
• At this point in the operation of the machine, it is safe to apply full load to the engine.
NOTE: Wear hearing protection at all times when the engine is started with the
service valve open and air is flowing from the valve.