DORAN MODEL 8000
OPERATING AND SERVICE MANUAL
MAN0002-42 of 33
12
The CONV button changes the weight display unit. This is necessary in applications
where there is a need to read equivalent weights in different units.
The PRINT button tells the 8000 to transmit weight data from its data interface to a
printer, computer or other peripheral device.
The 8000 provides the capability of enabling or disabling either of these functions.
If an option is selected for a transmit prompt, "P d" or "CPd", the display will show
"PrtOUt" when serial data is sent to the printer or computer.
3.4.10 Total Number of Graduations (CtS)
Function Option Description
CtS 3 3000 total scale grads.
6 6000 total scale grads.
Selects the scale graduations for each capacity. By selecting either 3 or 6, the function
will provide 3000 or 6000 graduations throughout the list of capacities.
Remember that if the "44" mode is selected, only 3000 graduations is allowed.
3.4.10.A Extended Graduations (CtS)
Function Option
Description
CtS 10 10000 total scale grads.
To select 10000 graduations, press PRINT and 10000 graduations will be selected.
Note: The maximum resolution for the 8000 is limited to 10000d. All the super
precision capacities have been limited to 10000d.
3.4.11 Data Bits and Parity (d.b.P)
Function Option
Description
d.b.P 8 n 8 data bits and no parity
7 n 7 data bits and no parity
7 O 7 data bits and odd parity
7 E 7 data bits and even parity
The Data Bits and Parity parameter selects the number of data bits and parity for each
character transmitted. For error checking, a parity bit can be selected for device(s) that
require it.
3.4.11.A Clear To Send Enable (hSh)
Function Option
Description
hSh OFF Clear to send disabled
ON Clear to send enabled