DORMA
23
ED 100/250
12. Parameterisation / Service
Theoperatorisreadyforoperationwithbasicparametersas
soonasthelearningcyclehasbeenperformedsuccessfully.
Thesystemalsoenablesyoutoadaptthedrivingparameters
totheprevailingconditionsandtoactivateextended
functions.Itisadvisabletoadapttheseparameterstothe
customer'srequirementsduringthecommissioningofthe
system.
< 3s Quit
> 3s Reset
< 3s
> 3s
LEARN
> 8s
Fact-Setup
> 3s
PRG
Parameters/Display Range Unit
factory setting
= bold print
Explanation
Configuration
Wayofmounting
0to1
0
Lintelmountingonhingesidewithslidechannel,pull-version
1 Lintelmountingonoppositehingesidewithstandardarm,
push-version
Linteldepth
ED 100: -3 to 30
ED 250: -3 to 50
0
Thelinteldepthisadjustedinstepsof10mm.
Considertheinstallationdrawingstofindtherequireddimension.
Door-leafwidth
ED 100: 7 to 11
ED 250: 7 to 15
10
Therebateisincludedinthedoor-leafwidth.
Thedoorwidthisindicatedinstepsof100mm.
Doortype
0to4
0
Single-leafdoor
1 Double-leafdoor,activeleaf,withrebate(overlapping)
2 Double-leafdoor,passiveleaf,withrebate(overlapping)
3 Double-leafdoor,activeleaf,withoutrebate
4 Double-leafdoor,passiveleaf,withoutrebate
Driving parameters and functions
Openingspeed
ED 100: 8 to 50
ED 250: 8 to 60
(inLow-Energy
Modereduced
to25°/sec.
respectively)
Degrees/
Second
25
TheopeningspeedreferstoAutomaticmode.Abidebycountry-
specificlimitsandcheckafteradjustment.Thefulladjustablerange
isonlyavailablewhentheUpgradeCardFull-Energyisinstalled.You
canalsoadjustthespeedviathisparameter.Aninternalmonitoring
functionchecksiftheselectedadjustmentsareadmissible.Incase
theadjustedparameterexceedstheadmissiblevalue,theadjusted
andtheoperativevaluearedisplayedalternately.
Closingspeed
ED 100: 8 to 50
ED 250: 8 to 60
(inLow-Energy
Modereduced
to25°/sec.
respectively)
Degrees/
Second
25
TheclosingspeedreferstoAutomaticmode.Abidebycountry-
specificlimitsandcheckafteradjustment.Thefulladjustablerange
isonlyavailablewhentheUpgradeCardFull-Energyisinstalled.Also
thespeedcanbeadjustedviathisparameter.Aninternalmonitoring
functionchecksiftheselectedadjustmentsareadmissible.Incase
theadjustedvalueexceedstheadmissiblevalue,theadjustedandthe
operativevaluearedisplayedalternately.