Page #8 background imageLoading...
Page #8 background image
DORMA
DORMA
8
DORMA
ED 100/250
4. Accessories
Electrical connection
ApartfromthebroadrangeofDORMAaccessories,also
othermanufacturersoffervariousactivators,lockingdevices,
safetysensorsandfurtheraccessoriesthatarecompatible
withED 100andED 250operators.Allaccessoriesthatare
approvedbyDORMAforapplicationatED 100andED 250
operatorsarelistedonthepositivelistforaccessories.
Pleasefindthecurrentversionofthepositivelistinour
swingdooroperatorproductrangeatwww.dorma.com.
DORMAcannotensurethecompatibilityofdevicesthatare
notlistedonthepositivelist.Ifthesecomponentsareused
nonetheless,itmighthappenthatthefullrangeoffunctions
isnotavailableorthattheoperatorworksimproperly.
Furthermoretheoperatorortheconnectedcomponentmight
bedamaged.
Seelimitationofliabilityonpage3.
Activator
Ingeneralwerefertothefollowingdevicesasactivators:
• Radarmotiondetectors
• Passiveinfraredmotiondetectors
• Pushbuttons
• Switches
• Sensors
• Radiosystems,infraredreceivers
• Accesscontrolsystems
• Telephonesystemsandintercoms
Minimum requirements
Operatingvoltagewithpowersupplyviaoperator:
24VDC+/-10%
Pulsewidth:
min.200ms
Potential-freeoutput
(Wheninstalledatinternalsignalinput,external
detectororNight-/Bank)
Energisedoutput(telephonesystems):
8-24VDC/AC+10%
Locking device
Ingeneralwerefertothefollowingdevicesaslocking
devices:
• Electricstrikeplates
• ElectricstrikesMotorlocks
• Multi-pointlockingdevicewithfeedbackcontact
• Doormagnets
Motorlockswithoutfeedbackcontactcanbedirectly
connectedtotheoperatoraslongasthedelayedopeningfor
thelockingmechanismamountstolessthan4seconds.In
ordertoensurethattheoperatorandthelockingdevicework
togetherproperly,thelockingdevicehastocomplywiththe
followingspecifications:
Minimum requirements
Operatingvoltagewithpowersupplyviaoperator:
24VDC+/-10%
Operatingvoltagewithexternalpowersupply:
max.48VDC/AC
Currentloadforrelaycontactoflockingdevice:
max.1A
Ratedforcontinuousduty:electricstrike:
min.30%
Ratedforcontinuousduty:motorlock:
100%
Powerconsumptionforaccessories:
Theoperatormayprovideamaximumof1.5Aat
24VDCforexternalaccessories.Incaseyouneed
morepower(evenifonlyforashortperiodoftime),an
externalpowersupplyunitisrequiredinordertoavoid
malfunctions.

Other manuals for Dorma ED 100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dorma ED 100 and is the answer not in the manual?

Dorma ED 100 Specifications

General IconGeneral
Adjustable Closing SpeedYes
Latching SpeedAdjustable
TypeElectromechanical
Power Supply230 V AC, 50 Hz
Fire RatedYes
BackcheckAdjustable
Delayed ActionAdjustable
Hold-Open FunctionYes
FinishSilver