ED 100/250
4. Accessories
Electrical connection
ApartfromthebroadrangeofDORMAaccessories,also
othermanufacturersoffervariousactivators,lockingdevices,
safetysensorsandfurtheraccessoriesthatarecompatible
withED 100andED 250operators.Allaccessoriesthatare
approvedbyDORMAforapplicationatED 100andED 250
operatorsarelistedonthepositivelistforaccessories.
Pleasefindthecurrentversionofthepositivelistinour
swingdooroperatorproductrangeatwww.dorma.com.
DORMAcannotensurethecompatibilityofdevicesthatare
notlistedonthepositivelist.Ifthesecomponentsareused
nonetheless,itmighthappenthatthefullrangeoffunctions
isnotavailableorthattheoperatorworksimproperly.
Furthermoretheoperatorortheconnectedcomponentmight
bedamaged.
Seelimitationofliabilityonpage3.
Activator
Ingeneralwerefertothefollowingdevicesasactivators:
• Radarmotiondetectors
• Passiveinfraredmotiondetectors
• Pushbuttons
• Switches
• Sensors
• Radiosystems,infraredreceivers
• Accesscontrolsystems
• Telephonesystemsandintercoms
Minimum requirements
Operatingvoltagewithpowersupplyviaoperator:
24VDC+/-10%
Pulsewidth:
min.200ms
Potential-freeoutput
(Wheninstalledatinternalsignalinput,external
detectororNight-/Bank)
Energisedoutput(telephonesystems):
8-24VDC/AC+10%
Locking device
Ingeneralwerefertothefollowingdevicesaslocking
devices:
• Electricstrikeplates
• ElectricstrikesMotorlocks
• Multi-pointlockingdevicewithfeedbackcontact
• Doormagnets
Motorlockswithoutfeedbackcontactcanbedirectly
connectedtotheoperatoraslongasthedelayedopeningfor
thelockingmechanismamountstolessthan4seconds.In
ordertoensurethattheoperatorandthelockingdevicework
togetherproperly,thelockingdevicehastocomplywiththe
followingspecifications:
Minimum requirements
Operatingvoltagewithpowersupplyviaoperator:
24VDC+/-10%
Operatingvoltagewithexternalpowersupply:
max.48VDC/AC
Currentloadforrelaycontactoflockingdevice:
max.1A
Ratedforcontinuousduty:electricstrike:
min.30%
Ratedforcontinuousduty:motorlock:
100%
Powerconsumptionforaccessories:
Theoperatormayprovideamaximumof1.5Aat
24VDCforexternalaccessories.Incaseyouneed
morepower(evenifonlyforashortperiodoftime),an
externalpowersupplyunitisrequiredinordertoavoid
malfunctions.