ED 100/250
2. Technical specifications
Thefollowingtechnicalspecificationswillhelpyoutocheckadditionallyifthesystemfulfilstherequirements.Youcanstart
mountingifthesystemcomplieswiththeparameters.
ED 100 EN2-4,push-version,fireprotection,EN2-4,pull-version,fireprotection Article-No.29222301
ED 250 EN4-6,push-version,fireprotection,EN4-6,pull-version,nospecifications Article-No.29202301
EN4-6,pull-version,fireprotection Article-No.29202302
EN4-5,pull-version,fireprotection Article-No.29202303
Required operating conditions
Ambienttemperature -15to+50°C
Onlysuitablefordry
environments
relativehumiditymax.93%
non-condensing
Powersupply 230VAC+/-10%50Hz
Classofprotection IP20
General specifications
Dimensions(WxHxD) 685x70x130mm
Min.distancebetweenhinges
(double-leafsystems)
1,400mm
Min.distancebetweenhinges
(double-leafsystems)
withESR(doorcoordinator)
1,450mm
Min.distancebetweenhinges
(double-leafsystems)with
VARIOCover
1,500mm
Operatorweight 12kg
Powersupplyforexternal
accessories
24VDC+/-10%,1.5A
Openingangle Max.110°
Inputs
Connections Max.1,5mm
2
Potential-freeactivator Insideandoutside
(NOcontact)
Night-/Bank(intercomsystem) 8-24VDC/AC+10%
Night-/Bank(keyswitch) NOcontact/NCcontact
Safetysensor Hingesideandopposite
hingeside(NCcontact)
Testsignalforsafetysensor Hingesideand
oppositehingeside
Deactivationofoperator
function(lockswitch)
NCcontact/NOcontact
Outputs
Connections Max.1,5mm
2
Potential-freestatusindicator Doorclosed
Dooropen
Malfunction
Integrated functions
Latchingaction Adjustablefrom5°-0°
Hold-opentime 0-30seconds
Night-/Bankhold-opentime 0-30seconds
Blockingbehaviourduring
closingcycle
Reversing/
Doorcloserfunction
Delayedopeningforlocking
mechanism(electricstrike)
0-1second/s
Lockingfeedbackcontact Motorlock
Windloadcontrol upto150N
Voltage-independentbraking
circuit
Adjustableviapotentiometer
Electroniclatchingactionpulse Forceadjustable
LEDstatusindicator green
red
yellow
-powersupplyavailable
-malfunction
-serviceintervalindicator
Integratedprogramswitch OFF
AUTOMATIC
PERMANENTOPEN
EXITONLY(onlyforsingle-
leafsystems)
Userinterfacewithinformation
display
Statusindicatorand
parameterisation
SlotforDORMAUpgradeCards Extensionoffunctionalrange
Updateinterface Firmwareupdate
TMP–Temperature
ManagementProgram
Overloadprotection
IDC–InitialDriveControl Drivingphaseoptimisation
Cyclecounter 0–1,000,000
(reasonablysubdivided)
PowerAssistFunction Servo-supportedmanual
opening
Push&GoFunction Thedooropenswhenitis
movedmanuallyby4°