Recycling and disposal
BoththeED 100/250 and its packing mainly
consist of recyclable raw material.
TheED 100/250 and the respective accessories
must not be disposed of as domestic waste.
Pleaseensurethattheoldapplianceandthe
respectiveaccessories(ifavailable)areproperly
disposedof.
Abidebytheprevailingnationalstatutoryprovisions!
Safety during mounting
• Theworkingareahastobesecuredagainst
unauthorisedaccessfromotherpeople.Fallingitems
ortoolsmightcauseinjuries.
• TheED 100/250 has to be secured against water and
other liquids.
• Inanycase,thewayofmountingandthemounting
equipment,likeforexamplescrewsandwallplugs,
havetobeadequatewithregardtothestructural
conditions(steelstructure,wood,concreteetc.).
• BeforemountingtheED 100/250, the door leaf has
to be checked with respect to proper mechanical
condition and smooth running.
The mounting of the ED 100/250 described herein is
only an example.
Structural or local conditions, available tools or other
conditions might suggest a different approach.
• Followingthesuccessfulinstallationofthesystem,the
settingsandtheproperfunctionoftheED 100/250
and the safety equipment have to be checked.
• Onlyspeciallyqualifiedstaffmayopenthepower
supplyhousing.
• DisconnecttheED 100/250 from power supply
(de-energise the system) before removing the cover of
the power supply housing.
Safety during commissioning
• Theprotectiveearthconductorhastobeconnected.
• Separatelysuppliedcomponentssuchastheprogram
switch,theEMERGENCYOFFpushbuttonand
activators(radarmotiondetectors,NIGHT-/BANKkey
switches)havetobemountedandconnected.
• Ensurethatthedoorleavesrunsmoothly.
• Theoperatorandthedoorleafmustbeproperly
linked.
Inspection and system approval
Beforethefirstcommissioninganddependingon
requirements,however,atleastonceayear,theED 100/250
has to be inspected by a properly qualified technician and
serviced if required.
A person trained by DORMA has to perform the inspection
and approve the system with the aid of the inspection book.
Therespectiveresultshavetobedocumentedandthefacility
operatorhastokeepthesedocumentsforatleastoneyear.
We would recommend taking out a maintenance
agreement with DORMA.
Briefing:
Followingtheadjustment,commissioningandfunctional
testingofthedoorsystem,theoperatinginstructionshave
tobehandedovertothefacilityoperatorandabriefinghas
tobemade.
Maintenance
Thesystemhastobede-energised/disconnectedfrompower
supplybeforeanykindofmaintenanceworkisperformed
(switchofffuse).
Pleaseconsidertheleafletregardingtheapplicationof
hold-opendevicesforfurtherinformationandinstructions
regardingtheapplicationoftheED 100/250 at fire and
smoke doors.
Care
Thesystemhastobede-energised(disconnectedfrompower
supply)beforecleaningthesystem.
Removepowerplugor,withpermanentpowersupply,switch
offfuse.
YoumaycleantheED 100/250 with a damp cloth and
standard commercial detergents.
Youshouldnotusescouringagentsforcleaningpurposesas
theymightdamagethesurfacefinish.
Payattentionthatnowaterorotherliquidsdroponorinto
theED 100/250.
Neverstickmetalobjectsintotheopeningsofthe
ED 100/250; otherwise you might sustain an electric shock.
Wear
Thefollowingwearpartshavetobeinspectedonceayear
andreplacedifrequired:
• Arm
• Slideshoe
• Slidechannel
Only use original spare parts.

Other manuals for Dorma ED 100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dorma ED 100 and is the answer not in the manual?

Dorma ED 100 Specifications

General IconGeneral
Adjustable Closing SpeedYes
Latching SpeedAdjustable
TypeElectromechanical
Power Supply230 V AC, 50 Hz
Fire RatedYes
BackcheckAdjustable
Delayed ActionAdjustable
Hold-Open FunctionYes
FinishSilver