EasyManuals Logo

Dormakaba ED-IG Series User Manual

Dormakaba ED-IG Series
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #9 background imageLoading...
Page #9 background image
9
ED250 01-2018DL4614-090
dormakaba ED250 IG Owner's Manual Chapter 6
. Lock stile
With door open, grasp lock stile of door and attempt
to move horizontally and vertically.
There should be no looseness in the door pivots or in
connections between door and operator.
. Breakout stop
Center pivoted in swinging doors may be supplied
with an emergency breakout stop or switch that will
allow the door to open in the direction of emergency
egress.
When the door is pushed into the breakout mode,
check that the door will not activate.
. Traffic patterns
Observe traffic patterns. Plan routing so people
enter and exit in a straight approach, directly toward
the door opening.
. Finger guard
If installed, inspect finger guard to see that it is
secure and in good repair.
. AAADM safety information label (Chapter )
An AAADM safety information label should be
affixed on the door or door frame in a protected,
visible location.
If you need additional decals or labels, contact your
local authorized Dorma USA, Inc. distributor.
WARNING
If there are any problems, discontinue door
operation immediately and secure the door in
a safe manner.
Call your local dormakaba USA Inc. distributor
for repair.
.. Review safety-related items and perform checks
as noted (Continued)
. Low energy power operated
swing doors
.. Review safety related items and perform checks
periodically as noted
TIPS AND RECOMMENDATIONS
Perform these checks while traffic is restricted.
. Housekeeping
Check door area for tripping or slipping hazards.
Make sure all door hardware is properly secured.
There should be no bulletin boards, literature racks,
merchandise displays, or other attractions in the
door area that would interfere with the use of the
door or encourage people to stop and stand in the
door area.
. Check all doors for damage.
. Door closing force
TIPS AND RECOMMENDATIONS
Reference ANSI/BHMA A156.19 standard, power
assist and low energy power operated doors.
Force to prevent the door from closing should not
exceed  pounds measured with a force gauge.
. Door safety signage
Refer to Chapter  for door safety signage
requirements. Chapter  documents safety
information (daily safety check) and annual
compliance inspection labels requirements.
. Lock stile
With door open, grasp lock stile of door and attempt
to move horizontally and vertically.
There should be no looseness in the door pivots or in
connections between door and operator.
. Breakout stop
Center pivoted in swinging doors may be supplied
with an emergency breakout stop or switch that will
allow the door to open in the direction of emergency
egress.
When the door is pushed into the breakout mode,
check that the door will not activate.
WARNING
If there are any problems, discontinue door
operation immediately and secure the door in
a safe manner.
Call your local dormakaba USA Inc. distributor
for repair.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dormakaba ED-IG Series and is the answer not in the manual?

Dormakaba ED-IG Series Specifications

General IconGeneral
BrandDormakaba
ModelED-IG Series
CategoryDoor Opening System
LanguageEnglish

Related product manuals