3.6 Door Pilot Interface (option)
The DPI function comprises a Bluetooth low energy module, the Door Pilot
Interface and an app for mobile end devices (smartphones): the Door Pilot App.
The Door Pilot App allows remote control of the door unit. The Health Check
function can also be used to check the current status of the unit. When using the
Door Pilot App, an additional lock, e.g. a floor lock, must be mounted on the door.
The customer bears sole responsibility for the safeguarding of access details
required to operate the door unit via the Door Pilot Interface. To protect against
misuse, it is necessary after installation of the door unit and the Door Pilot
Interface to log in using the Door Pilot App and to personalize the user key. If there
is to be no operation using the Door Pilot App, the Door Pilot Interface must be
deactivated or uninstalled.
For further information, see the terms and conditions (within the Door Pilot App).
3.7 Fire protection function
The fire protection function enables the sliding door to close safely in case of fire.
The function is controlled externally, e.g. via fire alarm systems or building
management systems. The function is only available for standard doors.
When the fire protection function is triggered, the door closes and is locked.
The door moves at creep speed due to the deactivated sensor system.
The following functions are no longer possible:
• Opening the door via the sensor system
• Change of the operating mode
• Fire brigade functionality
• Panic lock
• Close dead man’s switch
• Open dead man’s switch
• Pharmacy functionality
Opening the door is now only possible via emergency opening or the night/bank
impulse.