12
WN 059666 45532 - 07/2023
ES 250 PRO/ES 250 PRO FST
ES 400 PRO/ES 400 PRO FST
Operating instructions
3.8 Technical data
Connection voltage: 230 V AC + 10% -15% 50 Hz
Fuse supplied by the customer: 10 A
Protection class: IP20
Operating noise: <47 dB(A)
Permissible humidity: 93% relative humidity, non-condensing
Operating temperature:
-20°C to +60°C
Program inputs:
Off, Automatic, Permanently open, Partly open,
Exit
Tested load changes 1.5 million
Power supply
for external devices
- With mains operation
with 180 W power supply unit:
with 130 W power supply unit:
24 V DC/2A
24 V DC/2A
- With power failure in battery mode
with 180 W power supply unit:
with 130 W power supply unit:
21–27 V DC/2A
21–27 V DC/2A
Max. power consumption
with 180 W power supply unit:
with 130 W power supply unit:
180 W
130 W
Data and characteristics
Opening width, 1-leaf: 700–3000 mm
Opening width, 2-leaf: 800–3000 mm
Max. door weight, 1-leaf
with 180 W power supply unit:
with 130 W power supply unit:
1 x 250 kg
1 x 125 kg
Max. door weight, 2-leaf
with 180 W power supply unit:
with 130 W power supply unit:
2 x 200 kg
2 x 125 kg
Settings Adjustment range min. – max.
Opening/closing speed
with 180 W power supply unit:
with 130 W power supply unit:
10–90 cm/s
10–70 cm/s
OPEN/CLOSE creep speed: 3–9 cm/s
Brake ramp OPEN/CLOSE:
Braking deceleration OPEN:
0–9
Hold-open time/
night/bank
hold-open time:
0–180 s
Night/bank delayed opening: 0–10 s
Partial opening: 25–800 cm
Creep speed distance
OPEN/CLOSE:
0–30 cm
Acceleration OPEN/CLOSE: 0–9
Force limitation OPEN/CLOSE: 50–310 N