13
WN 059666 45532 - 07/2023
ES 250 PRO/ES 250 PRO FST
ES 400 PRO/ES 400 PRO FST
Operating instructions
3.9 Optional components
3.9.1 Key switch
The key switch can be configured by the service technician.
Each of the 4 switching options can be individually configured according to
customer requirements. 3 frequently used configurations are provided.
Standard Fire brigade circuit FIA
Left
<3 sec.
Off
FIA test run
OUTPUT deactivated
Left
>3 sec.
Electrical fault lock
Close dead man’s
circuit
---
Right
<3 sec.
Night/bank impulse Fire brigade switch
FIA test run
OUTPUT activated
Right
>3 sec.
Electrical fault
unlock
Open dead man’s
circuit
---
Individual configuration
Left <3 sec.
Left >3 sec.
Right <3 sec.
Right >3 sec.
3.9.2 Night/bank activator
The night/bank activator is used to open the door unit from outside when it is
switched off. Depending on the model, the activator is operated using a key or
electronically (e.g. with a credit or debit card). The activator is located outside near
the door unit. To open the door from inside after using the night/bank activator, an
activator such as a push button must be actuated if Off operating mode is set. In
Exit operating mode, the door opens automatically.
3.9.3 Emergency stop button
The emergency stop button is used to stop the door unit immediately in an
emergency. The emergency stop button has a red actuation element on a yellow
background and is located near the door unit. The emergency stop button must not
be used on doors on escape and emergency routes.