1. Safety and Compliance
1.1 Safety Information
WARNINGS
• Live parts inside.
• The handling and installation of this device is recommended for a professional.
• Use of an unsuitable power supply unit may cause product failure or injury.
• Do not remove the cover plates or face plate.
• Ensure installation does not expose sharp edges of the product to users.
UL REQUIREMENTS
• If the unit is installed on a fire exit door the product installation shall be allowed only if
accepted by a local AHJ authority having jurisdiction and comply with NFPA 101.
• The unit is to be connected and controlled via a UL 294 or FWAX7 listed Access Control Unit.
• That the unit shall be installed in accordance to NFPA 70 along with any additional
requirements imposed by the local authority of jurisdiction.
• Do not connect the unit to a receptacle controller by a switch.
• If the unit is installed in conjunction with panic hardware the lock shall be installed in a
manner to not impair panic device operations.
• The unit shall be powered by a UL 294 or UL 2610 listed power supply with a Class 2 power
limited output.
• All factory tested grades were not evaluated by UL.
• UL1034 rating only applies when product is installed in a mortised application.
• UL10C rating only applies when product is installed in vertical position