Programming -3
Version 1.36
02/2004
1. The waterflow of the outlet valves.
2. Calibrate the coffee valve after installation of a new boiler/valve and installation.
See chapter 5A for boiler replacement.
3. Default auto switch-off time is 4 hours.
4. Selection of price line 0, 1 or 2 for optional payment systems.
5. Selection of price line 0, 1 or 2 for optional payment systems.
6. Selection of price line 0, 1 or 2 for optional payment systems.
7. Enable/disable button programming (the pot volume setting must be done by service device).
8. When set to [1] it is not possible to dispense hot water or coffee after the boiler temperature has
dropped under 70°C/158°F (Condition =T
set
-3°C/-5.4°F).
When set to [0] this limitation has been disabled.
9. The boiler temperature can be set between 83-96°C/181-205°F. It may be possible that the boiler LED
starts blinking when the temperature is decreased 4°C/7.2°F or more. (boiler temperature high fault).
Switch the machine off for a while when this occurs.
10. Enable/disable the pot function.
11. Pot volume in ml. The coffe pot is always portion controlled. The customer has to press the stop button
when less than 0.9 litre/30.4 floz. is needed. It is of course possible to set any given volume between 2
20 ml and 999 ml by means of the service device.
12. Coffee strength setting for the pot (version 2.09 and higher).
13. Select [Portion control] or [Continous flow] for the hot water button according to the customer wish.
The default setting is [Continous flow].
14. Cup volume hot water in ml.
15. Select [Portion control] or [Continous flow] for the coffee button (cup) according to the customer wish.
16. Cup volume coffee in ml.
17. Coffee strength setting. See also page 7 of this chapter for more information about the ratio.
Remarks installation sub-menu