Dräger Fabius Series User Manual

Dräger Fabius Series
38 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #3 background imageLoading...
Page #3 background image
Page 3 / 38
Index
Legal and regulatory perspective ........................................................................................................ 5
Known limitations of Dräger anesthesia devices regarding use in long-term ventilation ............. 6
1 General instructions ................................................................................................................... 6
2 Prerequisites & preparation ....................................................................................................... 6
2.1 Training of medical personnel ................................................................................................. 6
2.2 Location requirements ............................................................................................................. 7
2.3 Manual resuscitator ................................................................................................................. 7
2.4 Oxygen backup cylinder .......................................................................................................... 8
2.5 Evacuation of gases (Scavenging) .......................................................................................... 8
2.6 Disconnection of vaporizers & N
2
O ......................................................................................... 8
2.7 Infection prevention ................................................................................................................. 9
2.8 Filters & humidification ............................................................................................................ 9
2.9 Breathing bag ........................................................................................................................ 11
2.10 Water Trap - Waterlock 2 ...................................................................................................... 11
2.11 CO
2
absorber ......................................................................................................................... 11
2.12 System configuration / default settings .................................................................................. 12
3 Regular checks ......................................................................................................................... 13
3.1 System Test ........................................................................................................................... 13
3.2 System restart & refreshing internal memory ........................................................................ 14
3.3 Check for overall status and accessories .............................................................................. 14
4 Therapy ...................................................................................................................................... 15
4.1 Fresh gas flow ....................................................................................................................... 15
4.1.1 General recommendation high fresh gas flow ............................................................... 15
4.1.2 Additional fresh gas flow ................................................................................................... 15
4.1.3 Reduced fresh gas flow .................................................................................................... 15
4.2 Handling leakages ................................................................................................................. 17
4.3 Modes of operation ................................................................................................................ 17
4.3.1 Ventilation mode - Man / Spon ......................................................................................... 17
4.3.2 Discouraged use external Fresh Gas Outlet, Pause, and Monitoring mode .................. 18
4.4 Alarm volume 100% .............................................................................................................. 18

Table of Contents

Other manuals for Dräger Fabius Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dräger Fabius Series and is the answer not in the manual?

Dräger Fabius Series Specifications

General IconGeneral
TypeAnesthesia Workstation
ManufacturerDräger
Ventilation ModesSIMV
Flow ControlElectronic
Tidal Volume Range20 to 1400 mL (model dependent)
Respiratory Rate4 to 60 breaths/min
PEEP0-20 cmH2O
Gas SupplyO2, Air, N2O
Vaporizer Mounts2
MonitoringO2, CO2, N2O
DimensionsVaries by model
WeightVaries by model
ModelFabius Series
CategoryAnesthesia