Page #1 background image
Instructions for use
Fabius Tiro
WARNING
To properly use this medical device,
read and comply with these
instructions for use.
Anesthesia workstation
Software 3.n

Table of Contents

Other manuals for Dräger Fabius Tiro

Question and Answer IconNeed help?

Do you have a question about the Dräger Fabius Tiro and is the answer not in the manual?

Dräger Fabius Tiro Specifications

General IconGeneral
BrandDräger
ModelFabius Tiro
CategoryMedical Equipment
LanguageEnglish

Summary

Safety Information Definitions

For Your Safety and That of Your Patients

General Safety Information

Covers essential safety precautions and warnings for operating the medical device.

Product-Specific Safety Information

Details safety warnings and precautions specific to the Fabius Tiro device.

Application

Operating Concept

Control Panel

Describes the main elements and functions of the device's control panel.

Screen Display

Details the information presented on the main screen for anesthesia and ventilation.

Selecting and Setting

Guides on how to select and set parameters, including changing ventilation modes.

Assembly and Preparation

Before First Operation

Outlines the initial steps required before operating the device for the first time.

Connecting the Gas Supply

Provides instructions for connecting the central gas supply and gas cylinders.

Assembling the Breathing System

Guides on assembling the breathing system, including preparing the ventilator and mounting the CO2 absorber.

Connecting the Sensors and Measurement Lines

Explains how to connect the O2 sensor, pressure sensor, and flow sensor.

Instructions for Mounting the Accessories

Provides guidelines for mounting various accessories onto the device, considering weight limits.

Getting Started

Daily Checkout and Pre-Use Checkout

Outlines the procedures for daily and pre-use checks to ensure device readiness.

Switching On

Details the process of switching on the anesthesia workstation and the initial system test.

Checking the Readiness for Operation

Explains how to interpret the results of the system test to determine device readiness.

Operation

Setting the Fresh-Gas Flow

Guides on how to adjust the fresh-gas flow settings before selecting a ventilation mode.

Setting the Anesthetic Gas Concentration

Details the procedure for setting the concentration of anesthetic gases using the vaporizer.

Ventilation

Covers setting up gas delivery and ventilation according to patient status.

Alarms

Alarm Signaling

Explains how alarms are signaled optically and acoustically on the device.

Alarm Priorities

Details the priority levels assigned to different alarm messages and their required actions.

Monitoring

Configuration

Troubleshooting

Locating and Remedying Leakages

Provides methods for identifying and fixing leakages in the breathing system and device.

Power Supply Failure

Addresses issues related to mains power failure and internal battery operation.

Ventilator Failure

Details steps to take when the ventilator fails or needs to be bypassed.

Failure of the O2 Sensor

Explains causes for O2 sensor failure and faulty calibration, with remedies.

Alarm – Cause – Remedy

Lists common alarms, their causes, and recommended remedies for troubleshooting.

Cleaning, Disinfection and Sterilization

Maintenance

Technical Data