1 [F]
2 [R]
3 [2ND]
4 [3RD]
5 [4TH]
6 [5TH]
F
R
2*4
3*4
5
MFO1
MFO2
P15
0V
MOCM
MOCP
17 [FWD]
19 [REV]
24 [MFI1]
25 [MFI2]
26 [MFI3]
11 [MFO1]
13 [MFO2]
18 [P15]
10 [0V]
14 [MFO COM]
12 [MFO CLAMP]
LED INDICATORS
GRAY
BLUE
YLW
ORG
BROWN
VIOLET
WHT
VF6100
SERIES
STANDARD
VFD MAIN
CONTROL
BOARD
RUN
RELAY
FAULT
RELAY
RUN STATUS RELAY
FORM A CONTACTS
PICK UP ON RUN
CONTACTS SHOWN IN
STOP CONDITION
2A @ 250VAC
FAULT RELAY
FORM C CONTACTS
PICK UP ON FAULT
CONTACTS SHOWN IN
NO FAULT CONDITION
2A @ 250VAC
1
2
3
5
4
10561532 110VAC INPUT SIGNAL ISOLATOR BOARD.
10561533 24VAC INPUT SIGNAL ISOLATOR BOARD
FOR USE WITH STANDARD VF6100 SERIES VFD
CONNECTION DIAGRAM
SOLDER PAD
CONNECTIONS
TB1
WHT / GRAY
WHT / BLUE
WHT / YLW
22 AWG
300V
HOOK UP WIRE
DRIVE END TERMINATED
WITH RING TERMINALS
14 AWG WIRE
MAXIMUM
TRAVEL LIMIT
SWITCHES
IF REQUIRED
RED
BLK
WHT / BLK
WHT / RED
10561532 110V INPUT ISOLATOR
OR
10561533 24V INPUT ISOLATOR
MOUNTED INSIDE
VF6100 HOUSING
PROG
OUTPUT 1
PROG
OUTPUT 2
10
11
12
13
14
16 [ACN]
PROGRAMMABLE
OUTPUT NO.1
FORM C CONTACTS
2A @ 250VAC
PROGRAMMABLE
OUTPUT NO.2
FORM C CONTACTS
2A @ 250VAC
110 vac NEUTRAL
G
G
R
R
R
R
R
R
R
R
R
17 [TL1]
Y
18 [TL2]
Y
REV.0 9-2-98
REV.1 10-9-98
SLOWDOWN LIMITS ADDED
GENERAL CONNECTION DIAGRAM.
FWD SLOWDOWN
LIMIT
REV SLOWDOWN
LIMIT
7 [MFI1]
8 [MFI2]
9 [MFI3]
15
MFI1
MFI2
MFI3
27 [MFI4]
28 [MFI5]
ESTOP
110 vac HOT
110 VAC CONTROL
SIGNAL INPUTS
RELAY CONTACT OR
SWITCH CLOSURE
ESTOP CONTACT SHOWN
IS AN EXTERNAL RELAY
THE ESTOP CONTACT
MAY BE N/O OR N/C.
THIS INPUT CAN BE PROGRAMMED
TO CAUSE AN ESTOP FOR EITHER
CONDITION
29 [MFI6] ESTOP
RESET
23 RESET
RESET IS A MOMENTARY
CONTACT CLOSURE TO RESET
A FAULT
REV.2 7/15/00
ESTOP INPUT RELOCATED
NOTE X
NOTE X: DO NOT MAKE ANY EXTERNAL CONNECTIONS
IN PARALLEL WITH ISOLATOR PCB'S OUTPUT.