Figure 3: Telephone Connection
RED (R)
GREEN (T)
GRAY (R)
BROWN (T)
RJ-31X
RING
TIP
CONTROL PANEL
Incoming
Phone line
Handset
RI
TI
T1
R1
TIP
RING
4
321
5
3G4010
TIP T1 R1
RING
Figure 4: Power Supply and Supervision Wiring Diagram
Figure 5:
(BLK/WHT) +13.8VDC
(BLK ) GND
Control
Panel
EOL
Resistor
See Note 3
DSC
RM-2
RELAY
NC
C
NO
ZONE
TERMINALS
(See Note 1)
- +
+12VDC
GND
CONTROL PANEL
Aux Power
+ -
DSC
Supervision
Relay
See Note 2
17
16
151412
18
13
11
1097 86
19
Z4
Z3Z2
COM
20
Z1
AUX
+
PGM
3
PGM
1
PGM
4
COM
3G4010
PGM
3
DC IN
+ -
Power Adaptor
NOTES:
1. Program the zone/point as “Supervisory” type
with keypad only annunciation when in alarm.
Do NOT use a zone/point that is normally used
for 2-wire smoke detectors.
2. The power supervision relay (RM-2) is only
used when the 3G4010 is not powered by the
control panel. When the radio is powered by
the control panel, the relay is not required since
a loss of input power will generate a signal to
the CMC.
3. Output 4 on the 3G4010 must be set as “Active
High” (default).
4. This equipment has no mains on/off switch. The
plug of the direct plug- in power supply is
intended to serve as the disconnecting method
if the equipment must be quickly disconnected.
Ensure that access to the mains plug and
associated mains socket/outlet, is never
obstructed.