[029] Cellular 2 Test Transmission
Default (00)
Program 00 to disable this event transmission or FF to enable. See System Test Options (previous page) for details on set-
tings.
NOTE: The time interval (in minutes) between periodic tests is programmed in section [125] (Ethernet) and section [225]
(cellular).
[030] FTC Restore
Default (FF)
Program 00 to disable this event transmission or FF to enable. This event will occur when an FTC Trouble on the system
restores.
[033] Communicator Firmware Update Begin
Default (FF)
Program 00 to disable this event transmission or FF to enable. This event will occur when a communicator firmware update
begins.
[034] Communicator Firmware Update Success
Default (FF)
Program 00 to disable this event transmission or FF to enable. This event will occur when a communicator firmware update
has completed successfully.
Table 15: System Firmware Update Failure
Event
SIA
Identifier
SIA
ReportingCode
CID
Qualifier
CID
Event
Code
CID
Reporting
Code
CID
User/Zone
[037] System FW Update Fail LU 0000 1 9 04 003
NOTE: The communicator will report ´System Update Fai only if the panel goes offline after a remote firmware update ses-
sion has started.
[095] SA Incoming Local Port
Default (0C14/3092)
[096] SA Outgoing Local Port
Default (0C14/3093)
[097] SA Call Up IP
Default (000.000.000.000)
[098] SA Call Up Port
Default (0000)
[099] SA Password
Default (FFFFFFFF)
Ethernet Receiver 1 Options
[100] Ethernet Receiver 1 Enabled
Option 1: Default ON
ON: Ethernet receiver 1 is enabled.
OFF: Ethernet receiver 1 is disabled.
Option 2: Ethernet receiver 1 Supervision Enabled Default OFF
ON: Ethernet receiver 1 is supervised and heartbeats are sent to Ethernet Receiver 1 based on the supervision interval pro-
grammed in section [107].
OFF: Ethernet receiver 1 is not supervised. When it is disabled, a commercial heartbeat is sent to the receiver once per
hour, regardless of the supervision type selected, residential or commercial.
[101] Ethernet Receiver 1 Account Code
Default (0000000000)
The account code is used by the central station to distinguish between transmitters. This account code is used when trans-
mitting heartbeat signals to the central station receiver. Signals received from the panel will use the control panel account
number.Valid range: 0000000001-FFFFFFFFFE. Programming all 0’s or all F’s will cause a module configuration trouble.
30

Table of Contents

Other manuals for DSC LE2080

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC LE2080 and is the answer not in the manual?

DSC LE2080 Specifications

General IconGeneral
BrandDSC
ModelLE2080
CategorySecurity System
LanguageEnglish

Related product manuals