[227] Voice Call Timeout
Default (00)
Valid entries from 00 to FF.
[228] Voice Call Back Time
Default (0A)
Valid entries from 00 to FF.
[229] Voice Call Back Number
________________________________________
[237] Primary Cellular DNS IP
Default (000.000.000.000)
[238] Backup Cellular DNS IP
Default (000.000.000.000)
Command and Control Options
[301] Command and Control Toggle Options
[1] SMS Notification (ON)
[2] Serial Communication Port enabled (OFF)
[3] SMS Command and Control Default(ON)
[4] Interactive (OFF)
[5] SMS Character Format (OFF)
[6] Long SMS Message Handling Default (OFF)
[7] Reserved
[8] Reserved
[308] Outgoing SMS Retry Attempts
Default (19) Valid entries from, 00 to FF.
[309] Outgoing SMS Retry Counter
Default (000F) Valid entry: 0000 - FFFF.
[311]-[342] SMS Phone Number 1-32
______________________________________________
[343]-[374] SMS Phone Number 1-32 Toggle
Options
[1] SMS Notification Alarm/Restore Default (ON).
[2] SMS Notification Tamper/Restore Default (ON)
[3] SMS Notification Opening/Closing Default (ON)
[4] SMS Notification System Maintenance Default (ON)
[5] SMS Notification System Test Default (ON)
[6] SMS Notification Internal Events Default (ON).
[7] SMS Notification Enabled Default (ON).
[8] SMS Command and Control Enabled Default (ON)
[375]-[406] SMS Phone Number 1-32 Partition
Assignment
Default (00) Valid range:00 - FF.
00 - Global; 01-32 - Partition; FF - Disabled
[420] Serial Port Baud Rate ('R' models only)
Default (05)
01=9600 Baud; 02=19200 Baud; 03=38400 Baud;
04=57600 Baud; 05=115200 Baud
[421] Serial Port Settings ('R' models only)
[1] Parity Enabled (OFF)
[2] Parity Type (OFF-Even Parity)
[3] 2 Stop Bit s (OFF-1 Stop Bit)
[4] Flow Control (OFF)
[422] Integration Identification Number
[423] Session 1 Integration Access Code
Default (12345678) Valid range: 00000000 - FFFFFFFF
[424] Session 1 SMS Label
Default (11111111)
______________________________________________
[425] Session 1 Integration Toggle Options 2
[1] Integration Over Serial Port (ON)
[2] Integration Over Cellular (OFF)
[3] Integration Over Ethernet (OFF)
[4] Type 2 Encryption (OFF)
[5] Integration Protocol (ON)
[6] Interactive Protocol SMA (OFF)
[7] Reserved
[8] Interactive Encryption for SMA (ON)
[426] Session 1 Integration Toggle Options 3
[1] UDP Polling (OFF)
[2] TCP Polling (OFF)
[3] Real-time Notification (OFF)
[4] Notification Follows Poll (OFF)
[5] Reserved
[6] Reserved
[7] Reserved
[8] Reserved
[427] Session 1 Interactive Polling Interval
Default (000A) Valid range: 0000 - FFFF seconds.
[428] Session 1 Integration Server IP
Default (000.000.000.000)
[429] Session 1 Integration Notification Port
Default (0C00/3072) Valid range: 0000 - FFFF.
55

Table of Contents