EasyManua.ls Logo

DSC PC2585 - Page 51

DSC PC2585
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
47
PC2585 v
1.1R
[42] Group A Access Code Assignment
Page 33
If a Zone Light is ON, then that Access Code is assigned to Group A.
The Master Code (Access Code 1)
must be assigned to both Group A and Group B in order for split arming to function properly.
Default
ON Access Code 1
ON Access Code 2
ON Access Code 3
ON Access Code 4
ON Access Code 5
ON Access Code 6
ON Access Code 7
ON Access Code 8
[43] Group B Access Code Assignment
Page 33
If a Zone Light is ON, then that Access Code is assigned to Group B.
The Master Code (Access Code 1)
must be assigned to both Group A and Group B in order for split arming to function properly.
Default
ON Access Code 1
ON Access Code 2
ON Access Code 3
ON Access Code 4
ON Access Code 5
ON Access Code 6
ON Access Code 7
ON Access Code 8
[44] Number of Rings Before Answer and Downloading Configuration
Page 34
This section configures the system for downloading functions. Program the number of rings to be allowed
before the system will answer an incoming call from the downloading computer with Zone Lights 1 through 4.
To turn a Zone Light ON or OFF, press its corresponding number key. If the light is OFF when the key is
pressed, the light will come ON; if the light is ON when the key is pressed, the light will be shut OFF.
The default setting for the number of rings is 15. The minimum number of rings is 1; at least one light must be
ON. The maximum number of rings is 15 (all lights ON).
Access Codes 9 through 16 are
permanently assigned to Group A.
Access Codes 9 through 16 cannot
be assigned to Group B.
Number of Rings Default
123456789101112131415
Zone Light 1 On Off On Off On Off On Off On Off On Off On Off On
Zone Light 2 Off On On Off Off On On Off Off On On Off Off On On
Zone Light 3 Off Off Off On On On On Off Off Off Off On On On On
Zone Light 4 Off Off Off Off Off Off Off On On On On On On On On
Default Zone Light ON Zone Light OFF
ON Zone Light 1 Set light patterns for number of rings as described in table above.
ON Zone Light 2 Minimum number = 1
ON Zone Light 3 Maximum number = 15 (all lights on)
ON Zone Light 4 At least one light must be on.
OFF Zone Light 5 Downloading enabled Downloading disabled
OFF Zone Light 6 User initiated call up No user initiated call up
OFF Zone Light 7 Answering machine connected No answering machine
OFF Zone Light 8 Call back enabled Call back disabled

Table of Contents

Related product manuals