Viewing Trouble Conditions
The control panel continuously monitors a number of possible trouble conditions. If one of these trouble
conditions occur, the keypa d will b e ep twic e every 10 seconds until you press any key on the keyp ad.
Troubles can only be vi ewe d when the system is in the disarmed state. If a troubl e occurs whil e the
system is armed, enter your a cc ess cod e to disarm the system, then follow the procedure outline d
below to determine the specific trouble.
NOTE: A TROUBLE condition reduces the security your system is designed to provide. Call your
installing company for service.
To view troubles from an LED Keypad:
A troubl e will be indi c ate d by the Troubl e light which will remain O N until the trouble condition is
cle are d. If you cannot determine or reme dy the c ause of the troubl e condition, conta ct your installer for
assistanc e.
To view the typ e of troubl e condition, press [
✱][2]. O ne or more zone lights will turn O N, indic ating the
various trouble conditions:
ZONE LIGHT TYPE OF TROUBLE
1 ................. Service require d. Press [1] and one or more of the zone lights corresponding to the
following system troubles will turn O N:
1. Low B attery 5. G eneral System Sup ervisory
2. Bell Circuit Troubl e 6. Not used
3. G eneral System Trouble 7. P C 5204 Low Battery
4. G eneral System Tamp er 8. P C 5204 A C F ailure
2 ................. Indicates the loss of A C power. When this trouble occurs, the Trouble light will turn
O N but the keypad buzzer will not sound.
3 ................. Tele phone line trouble.
4 ................. The p anel has failed to communicate with the c entral station.
5 ................. Zone fault. Press [5] and the zone light(s) corresponding to the faulted zones will turn ON.
6 ................. Zone tamper. Press [6] and the zone light(s) corresponding to the tamp ered zones will
turn O N.
7 ................. Low zone battery. Press [7] and the numb ers corresponding to the zones with
battery trouble will turn O N.
8 ................. Loss of time on system clock. To set the system time, following the instructions in
“ Setting System D ate and Time” on page 13.
To view troubles from an LCD Keypad:
From th e Re a dy st ate , us e the arrow (< >) ke ys to scroll to th e following mess a g e .
Press [✱] [2] to vi ew the troubl e. The messag e will re a d...
Use the arrow (< >) keys to view whi ch troubles are present on the system. O nce
you have scrolle d through the list of troubl es, press the [#] key to exit the Trouble
Viewing mode and return to the Ready state.
System Trouble
(*2) to View< >
View Trouble < >
“Trouble Message”