EasyManua.ls Logo

DSC Power 832 - Viewing Trouble Conditions; To View Troubles from an LED Keypad; To View Troubles from an LCD Keypad

DSC Power 832
19 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12
Viewing Trouble Conditions
The control panel continuously monitors a number of possible trouble conditions. If one of these trouble
conditions occur, the keypa d will b e ep twic e every 10 seconds until you press any key on the keyp ad.
Troubles can only be vi ewe d when the system is in the disarmed state. If a troubl e occurs whil e the
system is armed, enter your a cc ess cod e to disarm the system, then follow the procedure outline d
below to determine the specific trouble.
NOTE: A TROUBLE condition reduces the security your system is designed to provide. Call your
installing company for service.
To view troubles from an LED Keypad:
A troubl e will be indi c ate d by the Troubl e light which will remain O N until the trouble condition is
cle are d. If you cannot determine or reme dy the c ause of the troubl e condition, conta ct your installer for
assistanc e.
To view the typ e of troubl e condition, press [
][2]. O ne or more zone lights will turn O N, indic ating the
various trouble conditions:
ZONE LIGHT TYPE OF TROUBLE
1 ................. Service require d. Press [1] and one or more of the zone lights corresponding to the
following system troubles will turn O N:
1. Low B attery 5. G eneral System Sup ervisory
2. Bell Circuit Troubl e 6. Not used
3. G eneral System Trouble 7. P C 5204 Low Battery
4. G eneral System Tamp er 8. P C 5204 A C F ailure
2 ................. Indicates the loss of A C power. When this trouble occurs, the Trouble light will turn
O N but the keypad buzzer will not sound.
3 ................. Tele phone line trouble.
4 ................. The p anel has failed to communicate with the c entral station.
5 ................. Zone fault. Press [5] and the zone light(s) corresponding to the faulted zones will turn ON.
6 ................. Zone tamper. Press [6] and the zone light(s) corresponding to the tamp ered zones will
turn O N.
7 ................. Low zone battery. Press [7] and the numb ers corresponding to the zones with
battery trouble will turn O N.
8 ................. Loss of time on system clock. To set the system time, following the instructions in
Setting System D ate and Time on page 13.
To view troubles from an LCD Keypad:
From th e Re a dy st ate , us e the arrow (< >) ke ys to scroll to th e following mess a g e .
Press [] [2] to vi ew the troubl e. The messag e will re a d...
Use the arrow (< >) keys to view whi ch troubles are present on the system. O nce
you have scrolle d through the list of troubl es, press the [#] key to exit the Trouble
Viewing mode and return to the Ready state.
System Trouble
(*2) to View< >
View Trouble < >
“Trouble Message”